Product Overview
BOSHART INDUSTRIES
Telephone: 1-519-595-4444 - Toll Free: 1-800-561-3164
Fax: 1-519-595-4380 - www.boshart.com
2" DIAL PRESSURE GAUGES - LIQUID FILLED - LOWER & CENTER BACK MOUNT
Not For Conveying
Potable Water
• General Purpose - not for use with oxygen • Ideal for use where vibration or pressure pulsation occurs
• Accuracy: 3% - 2% - 3% Grade B • Bourdon Tube
• Brass or Lead Free Brass Connection • Polycarbonate Window
• Steel Case • Glycerine Filled
• Ambient Operating Temperature: -4 to 104
◦
F (-20 to 40
◦
C) • Maximum Media Temperature: 140
◦
F (60
◦
C)
NO LEAD INCRE- CASE
PART NO.
NO LEAD
PART NO.
RANGE
PSI
MENTS QTY
1/4" LM 1/4" CBM ( * 1/8" CBM)
PG-30-GNL 0-30 0.5
PG-60-GNL 0-60 1
0-100
1
PG-100-GNL
PGCBM-0-100-GNL *
PGCBM-1-100-GNL
0-100
1 100
PG-160-GNL 0-160 2
PG-200-GNL 0-200 2 100
INCRE- CASE
PART NO.
PART NO.
RANGE
PSI MENTS QTY
1/4" LM 1/4" CBM ( * 1/8" CBM)
PGCBM-0-100-G * 0-100 1
VACUUM / PRESSURE GAUGE
PGC-30-30-G
30Hg-0-30
0.5 100
2" DIAL STAINLESS STEEL PRESSURE GAUGES - LIQUID FILLED - LOWER & CENTER BACK MOUNT
• General Purpose - not for use with oxygen • Ideal for use where vibration or pressure pulsation occurs
• Accuracy: 3% - 2% - 3% Grade B • Bourdon Tube
• Stainless Steel Internals and Connection • Polycarbonate Window
• 304 Stainless Steel Case w/ vent plug • Glycerine Filled • Ambient Operating Temperature: -4 to 140
◦
F (-20 to 40
◦
C)
• Maximum Media Temperature: 212
◦
F (100
◦
C)
INCRE- CASE
PART NO. PART NO.
RANGE
PSI MENTS QTY
1/4" LM 1/4" CBM
PGS-100-G
PGSCBM-100-G
0-100 1 100
IMPORTANT: Liquid Filled Gauges are sealed with a rubber plug to prevent leaking during shipment. Upon
installation the tip of the plug must be cut off to allow the equalization of the internal gauge pressure to the
atmospheric pressure. FAILURE TO DO SO WILL ADVERSELY AFFECT THE FUNCTION OF THE GAUGE.
GLYCERINE TEMPERATURE RATINGS
”BII” gauges are filled with 100% (99.7% min.) glycerine, which starts to become viscous at +17
◦
C. As temp. decreases, the
more viscous glycerine becomes, causing the pointer to move slower to its correct position, it can take several minutes. At -5
◦
C
these ga uges no longer operate. For operating temps. less than -5
◦
C, glyce rine is mixed: 2 parts glycerine with 1 part water
(66.7%), which actually lowers the freezing point of the solution allowing the gauge to be used in temps. as low as -46
◦
C.
2-1/2" DIAL PRESSURE GAUGES - LOWER MOUNT
Not For Conveying Potable Water
• General Purpose - not for use with oxygen • Accuracy: 3% - 2% - 3% Grade B
• Brass or Lead Free Brass Connection • Bourdon Tube
• Steel Case • Acrylic Window
• Ambient Operating Temperature: 32 to 104
◦
F (0 to 40
◦
C) • Maximum Media Temperature: 104
◦
F (40
◦
C)
NO LEAD RANGE INCRE- CASE
PART NO. PSI MENTS QTY
1/4" LM
PG25-15NL 0-15 0.2 50
PG25-30NL 0-30 0.5 50
PG25-60NL 0-60 1 50
PG25
-100NL 0-100 1 50
PG25-160NL 0-160 2 50
PG25-200NL 0-200 2 50
PG25-300NL 0-300 5 50
PG25-400NL 0-400 5 50
PG25-600NL 0-600 10 50
PG25-100 0-100 1 50
PG25-160 0-160 2 50
PG25-200 0-200 2 50
US Rev. 1.1