User Manual

English 9
PRO.BOSE.COM
Tap Charts
Tap Charts
Individual Loudspeaker Continuous Output Level
Note: The following tap charts assume standing ear height at 1.5 meters (5 feet) in minimum overlap spacing.
Room reverberation could add as much as 4 dB system gain, which is not factored into the measurements.
Designing without room gain will ensure you don’t under-plan your design, and amp attenuation is possible at
the job site if you exceed the average room SPL target during measurement. Values below 70 dB are omitted,
select a higher tap.
DM2C-LP
DM2C-LP
(standing listener height)
Ceiling Height m 2.4 2.7 3 3.7 4 4.3 5 5.5 6 6.7 8 9.8
ft 8 9 10 12 13 14 16 18 20 22 26 32
TAP
1.2W 85 83 81 78 77 76 74 73 72 70
dB-SPL
2.3W 88 86 84 81 80 79 77 76 74 73 71
4.5W 91 89 87 84 83 82 80 79 77 76 74 72
9W 94 92 90 87 86 85 83 82 80 79 77 75
16Ώ 97 94 92 89 88 87 85 84 83 82 80 78
FS2C
FS2C
(standing listener height)
Ceiling Height m 2.4 2.7 3 3.7 4 4.3 5 5.5 6 6.7 8 9.8
ft 8 9 10 12 13 14 16 18 20 22 26 32
TAP
1W 87 84 82 79 78 77 75 74 73 72
dB-SPL
2W 90 87 85 82 81 80 78 77 76 75 73 75
4W 93 90 88 85 84 83 81 80 79 78 76 78
8W 96 93 91 88 87 86 84 83 82 81 79 81
16W 99 96 94 91 90 89 87 86 85 84 82 84
99 96 94 91 90 89 87 86 85 84 82 80
DM3C
DM3C
(standing listener height)
Ceiling Height m 2.4 2.7 3 3.7 4 4.3 5 5.5 6 6.7 8 9.8
ft 8 9 10 12 13 14 16 18 20 22 26 32
TAP
3W 88 86 84 81 80 79 77 76 75 73 72
dB-SPL
6W 91 89 87 84 83 82 80 79 78 76 75 72
12W 94 92 90 87 86 85 83 82 81 79 78 75
25W 98 95 93 90 89 88 86 85 84 83 81 79
98 95 93 90 89 88 86 85 84 83 81 79