User guide
Bose
®
ControlSpace
™
Designer
™
Software User Guide
Chapter 1: Configure the ControlSpace Designer network
9
Figure 1.9 - Change IP address in the Address setting window
Type 161 for the last three digits of the New IP Address, and
press Change.
Figure 1.10 - Successful IP address change dialog
You will see a dialog indicating a successful IP address change.
4. Power cycle the ESP-88 for the setting to take effect.
5. Connect the second ESP-88 to your Ethernet hub. This ESP-88
has an IP address ending in 160, so it will not conflict with the first
ESP-88 that you connected, which now has an IP address ending
in 161.
Use more than one CC-64
Each CC-64 is shipped with the IP address set to 192.168.0.176. As with
the ESP-88, if you are using more than one CC-64 you will need to
change the IP address of the additional CC-64s to avoid a conflict (for
example, to 192.168.0.177). Follow these steps to set IP addresses when
connecting multiple CC-64s to your local network:
1. Connect the first CC-64 to the Ethernet hub.