Number of alarm tracks:
Select the number of alarm tracks to be used in the partition. One alarm event
can be recorded in each alarm track. Accordingly, the number of alarms entered
can be recorded and archived. A partition can contain a maximum of 128 alarm
recordings.
If the option Ring mode (see page 64) is set for a partition, the latest alarm
recordings are always saved in the preset number. If the option Linear mode is
selected, the recording is stopped as soon as the total number of alarm tracks
has been recorded.
Already Used alarm tracks are displayed in the graphic next to the parameter.
Alarm recording:
Select which time intervals are to be covered for Pre-alarm and Post-alarm.
Alarm recording at:
You can select the alarm sensor that is to trigger a recording. You can also use
the motion and video alarm for a camera to trigger the alarm recording by
another camera.
Note
The alarm sensor must be active to be able to trigger the recording.
The alarm inputs and video loss alarms are activated on the page Alarm
sources (see page 67). The motion alarms are configured and activated
for each camera on the page Video content analysis (see page 70).
– Check the box for the alarm sensor that is to trigger a recording. The alarm
sensors selected are indicated by a check mark.
Note
The numbering of the check boxes for the alarm inputs corresponds to the
labeling of the alarm inputs on the VIP X1600 module. For the motion and
video loss alarm, the numbering corresponds to the labeling of the video
inputs.