Specifications
Bosch Security Systems | 2006-03 | V2.0 Installation
VIP X1600 | Installation and Operating Manual EN | 27
– You can start the configuration if a VIP X1600 module is shown in the list in
the left section of the window. To do this, click the entry for the module.
– Click the Network tab in the right section of the window. The current network
settings are displayed.
– In the IP address field, enter the required IP address (for example
192.168.0.16) and click the Set button at the bottom right of the window.
The new IP address is valid the next time you start the unit.
– If required, enter a new subnet mask and additional network data.
Note
You must restart to activate the new IP address, a new subnet mask or a
gateway address.
Restart
You can trigger the restart directly with the assistance of the Configuration Man-
ager:
– Right click the entry for the module in the list in the left section of the window
and select the Reset command.
Additional parameters
You can check and set additional parameters with the assistance of the Config-
uration Manager. You can find detailed information on this in the documentation
for this program.