AutoDome 800 Series HD PTZ Camera VG5 800 Series en Installation Manual
AutoDome 800 Series HD PTZ Camera Table of Contents | en 3 Table of Contents 1 Safety 7 1.1 Important Safety Instructions 7 1.2 Safety Precautions 9 1.3 Important Notices 9 1.4 Customer Support and Service 2 Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts 14 2.1 Unpacking 14 2.1.1 Parts List 14 2.1.2 Description 15 2.1.3 Tools Required 15 2.2 Pre-installation Checklist 15 2.3 Mount Power Supply Box 16 2.4 Route Wires and Attach Connectors 17 2.4.
en | Table of Contents 5 AutoDome 800 Series HD PTZ Camera Alarms and Relay Connections 54 5.1 Alarm Inputs 54 5.2 Connecting Alarms (inputs 1 or 2) 54 5.2.1 Connecting a Normally Open Alarm 54 5.2.2 Connecting a Normally Closed Alarm 54 5.3 Configuring an Open Collector Output 55 6 Using the AutoDome 800 Series 56 6.1 Overview of Features 56 6.2 System Requirements 56 6.3 Connecting the AutoDome 800 Series to the PC 57 6.
AutoDome 800 Series HD PTZ Camera Table of Contents | en 5 7.23 Lens Settings 86 7.24 PTZ Settings 87 7.25 Diagnostics 88 7.26 Preposition and Tours 89 7.27 Sectors 89 7.28 Miscellaneous 90 7.29 Logs 90 7.30 Audio 90 7.31 Pixel Counter 90 7.32 Advanced Mode: Recording 91 7.33 Storage Management 91 7.34 Recording Profiles 92 7.35 Retention Time 94 7.36 Recording Schedule 94 7.37 Recording Status 95 7.38 Advanced Mode: Alarm 95 7.39 Alarm Connections 95 7.
A en | Table of Contents AutoDome 800 Series HD PTZ Camera Keyboard Commands by Number 116 Index 117 F.01U.273.797 | 5.0 | 2012.08 Installation Manual Bosch Security Systems, Inc.
AutoDome 800 Series HD PTZ Camera Safety | en 1 Safety 1.1 Important Safety Instructions 7 Read, follow, and retain for future reference all of the following safety instructions. Heed all warnings on the unit and in the operating instructions before operating the unit. 1. Cleaning - Unplug the unit from the outlet before cleaning. Follow any instructions provided with the unit. Generally, using a dry cloth for cleaning is sufficient, but a moist fluff-free cloth or leather shammy may also be used.
en | Safety AutoDome 800 Series HD PTZ Camera 11. Power sources - Operate the unit only from the type of power source indicated on the label. Before proceeding, be sure to disconnect the power from the cable to be installed into the unit. – For battery powered units, refer to the operating instructions. – For external power supplied units, use only the recommended or approved power supplies. – For limited power source units, this power source must comply with EN60950.
AutoDome 800 Series HD PTZ Camera 1.2 Safety | en 9 Safety Precautions DANGER! This symbol indicates an imminently hazardous situation such as “Dangerous Voltage” inside the product. If not avoided, this will result in an electrical shock, serious bodily injury, or death. WARNING! Indicates a potentially hazardous situation. If not avoided, this could result in serious bodily injury or death. CAUTION! Indicates a potentially hazardous situation.
en | Safety AutoDome 800 Series HD PTZ Camera – Disconnect the unit's input connectors from outdoor equipment before disconnecting the grounding plug or grounding terminal. – Follow proper safety precautions such as grounding for any outdoor device connected to this unit. U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.
AutoDome 800 Series HD PTZ Camera Safety | en 11 Power lines - Do not locate the camera near overhead power lines, power circuits, or electrical lights, nor where it may contact such power lines, circuits, or lights. SELV All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits should only be connected to other SELV circuits.
en | Safety AutoDome 800 Series HD PTZ Camera destinées à fournir une protection raisonnable contre les interférences nuisibles quand l'appareil est utilisé dans une installation commerciale. Cette appareil génère, utilise et émet de l'energie de fréquence radio, et peut, en cas d'installation ou d'utilisation non conforme aux instructions, générer des interférences nuisibles aux communications radio. L’utilisation de ce produit dans une zone résidentielle peut provoquer des interférences nuisibles.
AutoDome 800 Series HD PTZ Camera 1.4 Safety | en 13 Customer Support and Service If this unit needs service, contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions. Service Centers USA Telephone: 800-366-2283 or 585-340-4162 Fax: 800-366-1329 Email: cctv.repair@us.bosch.com Customer Service Telephone: 888-289-0096 Fax: 585-223-9180 Email: security.sales@us.bosch.
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts AutoDome 800 Series HD PTZ Camera 2 Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts 2.1 Unpacking This equipment should be unpacked and handled with care. If an item appears to have been damaged in shipment, notify the shipper immediately. Verify that all the parts listed in the Parts List below are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative.
AutoDome 800 Series HD PTZ Camera 2.1.2 Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 15 Description This chapter details how to install an AutoDome Pendant Arm to a wall, a corner, or to a mast (pole). Any variations to the installation procedures are noted. See Section 3 Installing Roof Parapet and Pipe Mounts, page 33 for a Roof (Parapet) or Pipe mount installation. 2.1.3 Tools Required – 5 mm Allen wrench (supplied) – Small, straight-blade screwdriver - 2.5 mm (0.1 in.
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts AutoDome 800 Series HD PTZ Camera CAUTION! Select a rigid mounting location to prevent excessive vibration to the AutoDome camera. 2.3 Mount Power Supply Box Before mounting the Power Supply Box decide if you should wire the box through the holes in the bottom or back of the box. If wiring the box through the back, move the two (2) seal plugs to the bottom through the holes before mounting.
AutoDome 800 Series HD PTZ Camera 6. Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 17 Attach 3/4-inch (20-mm) NPS watertight pipe fittings (not supplied) to the bottom or back holes of the Power Supply Box through which you will run the power, video, and control data wires. 2.4 Route Wires and Attach Connectors Power wires must be routed to the left (front) side of the power supply box through a separate conduit.
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts 4. AutoDome 800 Series HD PTZ Camera Attach the supplied 3-pin Power Plug to the incoming power wires. See connector P101 in Table 2.1, Page 20, for wire connections. 5. Attach an RJ45 plug to the incoming Ethernet cable. If installing a Fiber Optic model, attach an ST fiber plug to the optic fiber cable.
AutoDome 800 Series HD PTZ Camera 2.4.1 Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 19 Power Supply Box Connections The following figure is a detailed illustration of the Pendant Arm Power Supply Box, which includes the fuse specifications.
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts No. P101 AutoDome 800 Series HD PTZ Camera Connector Pin 1 Pin 2 Ground Grounding Screw 115/230 VAC or Line NC Audio Audio Pin 3 Pin 4 Pin 5 Pin 6 Neutral 24 VAC Power In P105 Data/Audio Earth Not Used Ground P106 P107 Table 2.1 2.
AutoDome 800 Series HD PTZ Camera 1 2 3 4 Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 120/230 VAC Power In Ground Wire P101 Connector P107 Connector 5 6 7 21 Transformer In/Out Conduit (1/2 in. [15 mm] NPS Fitting 24 VAC Power Out to VG4-PA0 To properly wire the incoming high voltage and the outgoing low voltage lines, refer to this table: No.
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts AutoDome 800 Series HD PTZ Camera WARNING! Ensure that you connect the outgoing power supply wires to the P107 heater connectors (HN and HL). The heater power (XF103) fuse can handle a higher amperage (3.15 A) than the camera power (XF102) fuse (2.0 A). 6. Route the 24 VAC outgoing power supply wires into the VG4-PA0 power supply box through the conduit fitting on the left side of the box. 7.
AutoDome 800 Series HD PTZ Camera 1. Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 23 Compress the bottom hinge pin by pushing the pin lever downward and rotating it behind the Hinge Pin Stop. Figure 2.9 Pendant Arm to Power Box Hinge Alignment 2. Open the top hinge by pushing its pin lever up and holding it. NOTICE! Both Hinge Pins must be fully compressed to open (unlock) the hinges of the Pendant Arm and before proceeding to the next step. 3.
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts AutoDome 800 Series HD PTZ Camera 123 Figure 2.10 1. Pendant Arm connections to Power Supply Box Attach the earth ground wire (item 1 in the illustration above) to the grounding screw on the left side of the power box. 2. Connect the 6-pin Control/Audio cable, installed previously, to its mating connector P106 in the power box. 3.
AutoDome 800 Series HD PTZ Camera 6. Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 25 Connect the 3-pin Power In Plug, installed previously, to its matting connector P101 on the left side of the box. 7. If installing a Fiber Optic model attach the incoming ST fiber plug, installed previously, to its mating connector on the Fiber Optic Module in the power supply box. Then attach the Ethernet cable to its mating connector from the Pendant Connector Harness.
2.8 en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts AutoDome 800 Series HD PTZ Camera Installing the VG4-A-ARMPLATE This section provides instructions to install a wall, corner, or mast mount with the VG4-AARMPLATE Mounting Plate instead of a Power Supply Box. CAUTION! You must route the main power supply through a 120/230 VAC transformer (VG4-PSU1 or VG4-PSU2 power supply box) before connecting the power to a 24 VAC AutoDome. WARNING! A stud diameter of 6.
AutoDome 800 Series HD PTZ Camera 3. 2.8.1 Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 27 Ensure that the mounting plate is secure. Attach the Pendant Arm to the Mounting Plate The bottom hinge pin of the Pendant Arm is provided with a Hinge Pin Stop to hold the hinge open while attaching the arm to the Mounting Plate. 1. Compress the bottom hinge pin by pushing the pin lever downward and rotating it behind the Hinge Pin Stop. Figure 2.12 2.
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts Figure 2.13 AutoDome 800 Series HD PTZ Camera Pendant Arm Cables Cable 1 2 3 Cable Grounding Strap (black) 24 VAC Power (red) Relay Contacts (yellow) Cable 5 6 7 Cable Ethernet Video and Control (blue) Alarm Outputs (white) Alarm Inputs (gray) 4 (not used) Coax Video (black) 8 Audio In (green) (not used) 1. Route all incoming wires through one of the conduits at the bottom of the Mounting Plate.
AutoDome 800 Series HD PTZ Camera Figure 2.14 Ref. 1 2 3 4. Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 29 Mounting Plate - Inside Detail Description Grounding lug with two spade terminals Earth ground lug with crimp ring terminal Wire input conduit holes Connect the incoming 24 VAC power wires to the 5-pin, 24 VAC Power In mating connector (supplied with the Mounting Plate kit) for the Dome and for the Heater. 5.
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts AutoDome 800 Series HD PTZ Camera 12. Connect the Earth ground wire, if available, to the crimp ring terminal inside the Mounting Plate. Refer to Figure 2.14 above. Note: The Earth ground is not provided with the VG4-A-ARMPLATE kit; it is a ground connection made at the installed location. 13.
AutoDome 800 Series HD PTZ Camera 2.9 Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 31 Attach Pendant to Arm and Tighten CAUTION! The bubble is packaged with a protective plastic sheet. It is recommended that the bubble remain stored this way until it is ready to install. Limit handling the bubble, as any scratches can quickly affect visibility. NOTICE! Before attaching the AutoDome Pendant, visually inspect the dome and arm connectors for any blocked pin holes or bent pins. 1.
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts AutoDome 800 Series HD PTZ Camera CAUTION! If you feel any resistance when rotating the dome housing or when engaging the connector, stop immediately and start over. 4. Hold the Pendant housing in position while tightening the two (2) 5-mm Allen head mounting screws on top of the housing to 10-12 N-m (90-105 in.-lbs). CAUTION! You must tighten the two mounting screws to a minimum torque of 10-12 N-m (90-105 in.
AutoDome 800 Series HD PTZ Camera Installing Roof Parapet and Pipe Mounts | en 3 Installing Roof Parapet and Pipe Mounts 3.1 Unpacking 33 This equipment should be unpacked and handled with care. If an item appears to have been damaged in shipment, notify the shipper immediately. Verify that all the parts listed in the product's Parts List below are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. See Section 1.
3.2 en | Installing Roof Parapet and Pipe Mounts AutoDome 800 Series HD PTZ Camera Pre-installation Check List 1. Determine the location and distance for the power supply box based on its voltage and current consumption. See Section 4 Cable and Wire Standards, page 51 for wiring information and distances. 2. Use only UL listed liquid tight strain reliefs for conduits to the Power Supply Box to ensure that water cannot enter the box.
AutoDome 800 Series HD PTZ Camera Installing Roof Parapet and Pipe Mounts | en 35 Figure 3.1 Wall Mount Power Supply with Optional Trim Skirt 1. Use the wall mount template supplied in the packaging box to locate the four (4) mounting holes for the Power Supply Box. 2. Drill four (4) holes for the mounting anchors. If installing outdoors, apply a weatherproof sealant around each hole at the mounting surface. 3. 4. Place the Power Supply Box into the optional Trim Skirt.
en | Installing Roof Parapet and Pipe Mounts 3.3.1 AutoDome 800 Series HD PTZ Camera Attach Cover Door 1. Compress the bottom hinge pin by pushing the pin lever down and then rotate it behind the Hinge Pin Stop. The power box Cover Door provides a Hinge Pin Stop to hold the bottom hinge open while attaching the door. (FUSE) o (FUSE) HTR (FUSE) DOME 90 24V NC 24V GND TXD RXD C+ C- GND TXD RXD C+ C- Figure 3.2 Align Cover Door Hinge to Power Box 1 2 3 4 2.
AutoDome 800 Series HD PTZ Camera 3.4 Installing Roof Parapet and Pipe Mounts | en 37 Route Wires and Attach Connectors Power wires must be routed to the left (front) side of the Power Supply Box through a separate conduit. All video, control, and alarm wires must be routed through a second conduit to the right side of the box. See Section 4 Cable and Wire Standards, page 51 for methods of transmitting video and data, and for wire specifications.
en | Installing Roof Parapet and Pipe Mounts AutoDome 800 Series HD PTZ Camera P106 GND TXD RXD P105 C+ C- GND TXD RXD P104 P101 P102 P107 24V XF102 J103 (LED) 24V NC AGND A7 A6 A5 A4 A3 P103 XF103 DOME 54321 HTR P107 XF101 (FUSE) P101 AGND OUT 3 OUT 2 OUT 1 (FUSE) J101 J102 (FUSE) J102 P105 BNC C+ C- J101 P106 Figure 3.4 VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box Connected to Pipe Interface Board 1 2 3 4 5 6 F.01U.273.797 | 5.0 | 2012.
AutoDome 800 Series HD PTZ Camera 3.4.1 Installing Roof Parapet and Pipe Mounts | en 39 Wiring the Power Supply Box 1. Route the high voltage 115/230 VAC lines through the conduit fitting on the left side of the box. NOTICE! The Power Supply Box with transformer comes with a barrier that separates the high voltage side on the left from the low voltage 24 VAC side on the right. 2.
en | Installing Roof Parapet and Pipe Mounts AutoDome 800 Series HD PTZ Camera (FUSE) (FUSE) HTR (FUSE) DOME (GND) 24V NC 24V GND TXD RXD 1 2 3 4 F.01U.273.797 | 5.0 | 2012.08 Transformer Ethernet to Dome In/Out From Arm Harness C+ C- 5 6 7 8 In/Out ST Connector (Fiber) Power In Data In/Out Installation Manual Bosch Security Systems, Inc.
AutoDome 800 Series HD PTZ Camera 3.4.3 Installing Roof Parapet and Pipe Mounts | en 41 Power Supply Box Connections The following figure is a detailed illustration of the Roof or Pipe Mount Power Supply Box, 123 XF102 CONTROL IN/OUT P106 GND T XD RXD C+ C- 6 5 4 3 2 1 1 2 3 4 CONTROL TO DOM ME P105 GND T XD RXD C+ J103 J103 (LED) 24V NC 24V (FUSE)) DOME HTR P107 XF101 (FUSE)) P101 (FUSE)) J101 1 J102 5 4 3 2 1 XF103 which includes the fuse specifications.
en | Installing Roof Parapet and Pipe Mounts No. P101 AutoDome 800 Series HD PTZ Camera Connector Pin 1 Pin 2 Ground Grounding Screw 115/230 VAC or Line NC Audio Audio Pin 3 Pin 4 Pin 5 Pin 6 Neutral 24 VAC Power In P105 Data/Audio Earth Not Used Ground P106 P107 Table 3.1 3.
AutoDome 800 Series HD PTZ Camera Installing Roof Parapet and Pipe Mounts | en 43 Figure 3.6 Parapet Wall Mount Bracket and Roof Mount Plate 1 2 3 Pipearm 4 Parapet Wall Bracket 5 3/8-16 SS Hex Head Bolt (supplied) 6 Apply sealant around each fastener hole Roof Mount Plate Use a minimum of six (6) fasteners (not supplied). Eight (8) fastener holes shown. NOTICE! Fasteners are not supplied with the Roof Parapet Mount Kit since it depends on the material to which it is attached.
en | Installing Roof Parapet and Pipe Mounts AutoDome 800 Series HD PTZ Camera Figure 3.7 VG4-A-9230 Parapet Mount 1 2 3 4 5 7. End Cap with O-ring Parapet Pipe Arm 1/4-20 SS Cap Screw Down Pipe 10-24 SS Pan Head Screw Fold the Ethernet and power wires back at the front end of the arm and route them down and out through the Down Pipe. Then replace the End Cap. 8. Wrap at least five layers of Teflon tape around the Down Pipe threads. 9.
AutoDome 800 Series HD PTZ Camera Installing Roof Parapet and Pipe Mounts | en 45 12. Proceed to Section 3.7 Wire the Pipe Interface Board, page 46. NOTICE! Use a guy-wire to aid in stabilizing the Parapet Arm. Replace the 1/4 inch cap screw with a threaded 1/4-inch stainless steel eye bolt (not supplied). Loop the guy-wire through the eye bolt and attach both ends to anchor spots on the roof. See Figure 3.7, Page 44. 3.
en | Installing Roof Parapet and Pipe Mounts 7. AutoDome 800 Series HD PTZ Camera Thread the Pipe Cap onto the down pipe and tighten securely to prevent leaks. See Figure 3.9, Page 45. WARNING! You must thread the Dome Cap onto the pipe until it is tight. Failure to do so can result in damage or serious injury or death. 3.7 Wire the Pipe Interface Board This section provides instructions for connecting wires and cables to the Pipe Interface Board, as illustrated below.
AutoDome 800 Series HD PTZ Camera Installing Roof Parapet and Pipe Mounts | en Ref. Description 3 6-pin Alarm Input Flying Lead Connector P103 Wire Gauge Alarms In (1-2) 4 4-pin Alarm Outputs Flying Lead P102 Relay Out (1) 3.7.
en | Installing Roof Parapet and Pipe Mounts AutoDome 800 Series HD PTZ Camera WIRE 1 BROWN 3 ORANGE 4 GREEN WIRE 1 2 3 4 5 6 Figure 3.
AutoDome 800 Series HD PTZ Camera 1 2 3 3.8 Installing Roof Parapet and Pipe Mounts | en 49 Interface Board Retaining Screws (3) Pendant Mounting Screws (2) Attach Pendant to Pipe and Tighten CAUTION! The bubble is packaged with a protective plastic sheet. It is recommended that the bubble remain stored this way until it is ready to install. Limit handling the bubble, as any scratches can quickly affect visibility. 1.
en | Installing Roof Parapet and Pipe Mounts 3 4 3. AutoDome 800 Series HD PTZ Camera Rotate down to engage dome connector. Tighten the two (2) mounting screws to a minimum torque of 10-12 N-m (90-105 in.-lbs). Drop the Pendant down slightly to engage the dome hook and hinge pin of the Dome Cap, allowing the dome to rotate around the hinge pin. 4. Rotate the dome housing down to a vertical position and gently push upward to engage the connector on top of the dome housing.
AutoDome 800 Series HD PTZ Camera Cable and Wire Standards | en 4 Cable and Wire Standards 4.1 Power 51 115/230 VAC Copper Wire 4.2 To comply with local codes. Wire Distance Guide for Pendant 24 V to AutoDome VA / Watts 800 Series with IVA, Outdoor 60 / 55 14 AWG (2.5 mm) 16 AWG (1.5 mm) 18 AWG (1.0 mm) 58 m (190 ft) 36 m (119 ft) 23 m (75 ft) Table 4.1 Maximum Wire Distances from Power Supply to AutoDome 4.
en | Cable and Wire Standards AutoDome 800 Series HD PTZ Camera Ethernet Media Converter Fiber Type, SMF 8–10/125 µm SMF. Must meet or exceed fiber standard ITU-T G.652. Maximum Distance 20 km (12.4 miles) Requirement Media converter receiver (CNFE2MC/IN) at controller end of system Terminal Connection 4.4 Duplex LC or Single SC Audio Cables The AutoDome 800 Series is capable of receiving line input audio signals and transmitting it over a network.
AutoDome 800 Series HD PTZ Camera 1 2 3 4 5 6 Audio- (C-) Audio+ (C+) Earth Ground RxD TxD Signal Ground Cable and Wire Standards | en 7 8 9 53 AutoDome Data In/Out P105/P106 Connector Audio Out NOTICE! See Section 7.30 Audio, page 90 for audio configuration. Bosch Security Systems, Inc. Installation Manual F.01U.273.797 | 5.0 | 2012.
en | Alarms and Relay Connections AutoDome 800 Series HD PTZ Camera 5 Alarms and Relay Connections 5.1 Alarm Inputs The AutoDome provides two alarm inputs. Each input can be activated by dry contact devices such as pressure pads, passive infrared detectors, door contacts, and similar devices. The table below summarizes the size and distance wires. Wire Size Maximum Distance AWG mm feet meters 22 0.644 500 152.4 18 1.024 800 243.8 Table 5.
AutoDome 800 Series HD PTZ Camera Alarms and Relay Connections | en 55 Figure 5.2 N.C. Normally Closed Non-supervised Connections 1 2 Dry Contact Alarm Inputs 1 to 2 3 4 Dome Connector Ground 2. From the Alarm Connections page on the Settings Page (Section 7.39 Alarm Connections, page 95) the Alarm Input # to N.C. See the table below for contact and condition details. AutoDome Programmed N.C. 5.
6 en | Using the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Using the AutoDome 800 Series The AutoDome 800 Series transmits PTZ control commands and images over a TCP/IP network. It also allows users to configure the camera display settings, camera operating settings, and to configure the network parameters. The IP unit incorporates a network video server in the IP module. The primary function of the server is to encode video and control data for transmission over a TCP/IP network.
AutoDome 800 Series HD PTZ Camera Using the AutoDome 800 Series | en 57 NOTICE! The Web browser must be configured to enable Cookies to be set from the IP address of the unit. In Windows Vista, deactivate protected mode on the Security tab under Internet Options. You can find notes on using Microsoft Internet Explorer in the online Help in Internet Explorer.
en | Using the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Figure 6.1 AutoDome 800 Series System Configuration 1 2 3 4 AutoDome 800 Series IP Connection Network Switch Computer NOTICE! You can also use the Bosch Configuration Manager utility to configure the network settings for an AutoDome 800 Series camera. Go to www.boschsecurity.com to download the Configuration Manager software (part of the BVIP Lite Suite) and Operating Manual. 6.
AutoDome 800 Series HD PTZ Camera 6.4.1 Using the AutoDome 800 Series | en 59 Changing the Network Settings The AutoDome 800 Series has a default IP address of 192.168.0.1. To change the IP address or any network settings, you can use the Configuration Manager software or the AutoDome 800 Series server. NOTICE! Contact your local network administrator for a valid IP address, Subnet Mask, and a Gateway IP Address.
en | Using the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera NOTICE! Click the Help on this page? link if you need more information. 8. Click the Set button to save the settings. 9. Launch another instance of Microsoft Internet Explorer. 10. Type the original IP address followed by /reset (for example, http://192.168.0.1/reset) in the address bar and click Go to restart the AutoDome 800 Series. Once you restart the AutoDome 800 Series, use the new IP Address to access the Livepage. 11.
AutoDome 800 Series HD PTZ Camera 6.5.2 Using the AutoDome 800 Series | en 61 Guidelines for Implementing Intelligent Tracking Factors such as the viewing angle and unwanted motion (from trees, for example) may interfere with Intelligent Tracking operation. Use the following recommendations to ensure smooth Intelligent Tracking operation: – Mount/Mounting Surface Stability – Mount the camera in the most stable position.
en | Using the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Motion flag set on media item Discovery of storage not completed. If the information about recorded video is not cached, a discovery procedure is started in order find all recorded video. During this time, the “discovery” symbol is shown. While discovery is executed, gaps might be shown in places which the discovery has not yet reached.
AutoDome 800 Series HD PTZ Camera Using the AutoDome 800 Series | en Reference # Description Reference # Description 1 Tilts the camera up 8 Focus far2 2 Tilts the camera down 9 Focus near2 3 Pans the camera to the left 10 Iris close2 4 Pans the camera to the right 11 Iris open2 5 Pans and tilts the camera in all directions 12 6 Zoom out1 7 Zoom in1 63 Sets the PTZ speed for controls 1, 2, 3, 4, 5, 6, and 7 13 Moves the camera to pre-set shot numbers 1, 2, 3, 4, 5, and 6 1.
en | Using the AutoDome 800 Series 1. AutoDome 800 Series HD PTZ Camera If you want to delete the entries, click the delete icon in the top right-hand corner of the relevant field. 2. If you want to view a detailed log, click the icon in the top right-hand corner of the relevant field. A new window will open. 6.6.1 Entering a Keyboard Control Command The Aux Control tab is used to enter keyboard control commands.
AutoDome 800 Series HD PTZ Camera Using the AutoDome 800 Series | en 65 To View a Preset Shot: 1. Click the number of the scene you want to view using the on-screen keypad. 2. Click the Show Shot button. NOTICE! For more information about the AutoDome 800 Series settings and controls, click the Help on this page? link to open the AutoDome 800 Series online help. 6.6.2 Using Intelligent Tracking Intelligent Tracking continuously follows an individual or an object.
en | Using the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Scan 360 Click this button to start a continuous 360° pan. To stop the continuos pan, click a directional control in the View Control tab. Autopan Click this button to pan the AutoDome between user-defined limits. To set the left and right pan limits, refer to Section 7.24 PTZ Settings, page 87, so set the Autopan limits. To stop the continuos pan, click a directional control in the View Control tab.
AutoDome 800 Series HD PTZ Camera Using the AutoDome 800 Series | en 67 You can obtain additional information to help when you troubleshoot or fine-tune the unit. The values indicate the proportions of the individual functions on the encoder load, shown as percentages. Move the cursor over the graphic indicator. Some additional numerical values are also displayed. Bosch Security Systems, Inc. Installation Manual F.01U.273.797 | 5.0 | 2012.
en | Using the AutoDome 800 Series 6.10 AutoDome 800 Series HD PTZ Camera Recordings page Click Recordings to access the Recordings page from the Livepage or Settings page (the Recordings link is only visible if a storage medium has been selected). Selecting Recordings All saved sequences are displayed in a list. A track number is assigned to each sequence. Start time and stop time, recording duration, number of alarms, and recording type are displayed. To play back recorded video sequences: 1.
AutoDome 800 Series HD PTZ Camera Using the AutoDome 800 Series | en 69 Set bookmark Jump to the following bookmark Bookmarks are only valid while in the Recordings page; they are not saved with the sequences. All bookmarks are deleted when leaving the page. Bosch Security Systems, Inc. Installation Manual F.01U.273.797 | 5.0 | 2012.
7 en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series The SETTINGS page provides access to the configuration menu, which contains all the unit's parameters arranged in groups. You can view the current settings by opening one of the configuration screens. You can change the settings by entering new values or by selecting a predefined value from a list field.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 71 CAUTION! Do not use any special characters, for example &, in the name. Special characters are not supported by the system's internal recording management and may therefore result in the Player or Archive Player being unable to play back the recording. Password An AutoDome 800 Series is generally protected by a password to prevent unauthorized access to the unit. You can use different authorization levels to limit access.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Select Time server for a time server that works with the protocol RFC 868. 7.3 Basic Mode: Network The settings on this page are used to integrate the AutoDome 800 Series into an existing network. Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot. 1. 2. Make the desired changes. Click the Set and Reboot button.
AutoDome 800 Series HD PTZ Camera – Configuring the AutoDome 800 Series | en 73 HD low bandwidth Target bit rate: 2500 kbps Maximum bit rate: 5000 kbps Encoding interval: 30.00 ips – SD high quality / low latency Target bit rate: 2000 kbps Maximum bit rate: 4000 kbps Encoding interval: 30.00 ips – SD high quality Target bit rate: 1500 kbps Maximum bit rate: 3000 kbps Encoding interval: 30.00 ips – SD low bandwidth Target bit rate: 700 kbps Maximum bit rate: 1500 kbps Encoding interval: 30.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Storage medium 7.7 1. Select the required storage medium from the list. 2. Click the Start button to start the recording immediately. Basic Mode: System Overview The data on this page are for information purposes only and cannot be changed. Keep a record of this information in case technical assistance is required.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 75 NOTICE! Proper password protection is only guaranteed when all higher authorization levels are also protected with a password. If a live password is assigned, for example, a service and a user password must also be set. When assigning passwords, you should therefore always start from the highest authorization level, service, and use different passwords.
en | Configuring the AutoDome 800 Series 1. AutoDome 800 Series HD PTZ Camera First check whether the correct time zone is selected. If it is not correct, select the appropriate time zone for the system, and click the Set button. 2. Click the Details button. A new window will open and you will see the empty table. 3. Select the region or the city that is closest to the system's location from the list field below the table. 4.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 77 Display milliseconds If necessary, you can also display milliseconds. This information can be useful for recorded video images; however, it does increase the processor's computing time. Select Off if you do not need to display milliseconds. Alarm mode stamping Select On to display a text message overlay in the image in the event of an alarm.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Website language Select the language for the user interface here. Company logo Enter the path to a suitable graphic if you want to replace the manufacturer's logo. The image file can be stored on a local computer, in the local network or at an Internet address. Device logo Enter the path to a suitable graphic if you want to replace the product name.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 79 Show event log The event messages are displayed along with the date and time in a field next to the video image. Show system log The system messages are displayed along with the date and time in a field next to the video image and provide information about establishing and ending connections, for example. Allow snapshots Here you can specify whether the icon for saving individual images should be displayed below the live image.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera SC Settings Click the Default button to restore all camera settings to their original defaults. SC Data Click the default button to clear all preposition, privacy mask, and other user settings. Reboot device Performs a reboot of the AutoDome. There is a ten (10) second pause before the dome starts its homing phase. During the homing phase the camera pans left and right and tilts up and down. It also adjusts the lens focus.
AutoDome 800 Series HD PTZ Camera – Configuring the AutoDome 800 Series | en 81 DSL Target bit rate: 400 kbps Maximum bit rate: 500 kbps Encoding interval: 30.00 ips – ISDN (2B) Target bit rate: 80 kbps Maximum bit rate: 100 kbps Encoding interval: 30.00 ips You can change individual parameter values of a profile and you can also change the name. You can switch between profiles by clicking the appropriate tabs. CAUTION! The profiles are rather complex.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Encoding Interval The figure selected here determines the interval at which images are encoded and transmitted. The image rate in ips (images per second) is displayed next to the text field. Use the slide bar to select a frame rate from 30.00 ips to 1 ips. Expert Settings Use the expert settings to adapt the I-frame quality and the P-frame quality to specific requirements, if necessary. The setting is based on the H.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 83 SD stream options (use these options if a second H.264 stream is allowed): – H.264 BP+ bit-rate-limited Select this setting when using hardware decoders. The bit rate is limited to 1.2 Mbps. CABAC: off CAVLC: on GOP structure: IP I-frame distance: 15 Deblocking filter: on – H.264 MP SD Select this setting when using software decoders, PTZ and for rapid movements in the images.
en | Configuring the AutoDome 800 Series – AutoDome 800 Series HD PTZ Camera Picture quality: his setting allows you to adjust the image quality. Use the slide bar to choose a quality between Low and High. 7.21 Privacy Masks Privacy Masking is used to block out a specific area of a scene from being viewed. Masks can be configured as a gray area with four corners. You may define a total of 24 privacy masks.
AutoDome 800 Series HD PTZ Camera – Configuring the AutoDome 800 Series | en 85 Sodium Lamp Auto: Automatically adjusts for sodium vapor light to restore objects to their original color. – Sodium Lamp: Optimizes the sodium vapor light to restore objects to their original color. Red Gain The red gain adjustment offsets the factory white point alignment (reducing red introduces more cyan).
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera High Sensitivity Setting Night Mode Selects night mode (B/W) to enhance lighting in low light scenes. Select from the following options: – Off: Forces the camera to stay in Nigh Mode and transmit monochrome images. – On: The camera does not switch to Night Mode regardless of ambient light conditions. – Auto: The camera switches out of Night Mode after the ambient light level reaches a predefined threshold.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 87 Iris Polarity Capability to reverse the operation of the iris button on the controller. – Normal (default): iris controls operate normally. – Reverse: iris controls are reversed. Auto Iris Level Increases or decreases brightness according to the amount of light. Type a value between 1 and 15, inclusive. The default setting is 5. Maximum Zoom Speed Controls the zoom speed. The default setting is Fast.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Autopan Right Limit Sets the right Auto Pan limit of the camera. Use the preview window to move the camera to the right pan limit and click the button. The camera will not move past this limit when in Auto Pan Between Limits mode (AUX 2 ON). Tilt Up Limit Sets the upper tilt limit of the camera. Tilt Limits Click the Reset button to clear the upper tilt limit.
AutoDome 800 Series HD PTZ Camera 7.26 Configuring the AutoDome 800 Series | en 89 Preposition and Tours The AutoDome 800 Series can store up to 99 preset scenes and this section allows you to define the individual scenes that comprise a preposition tour. You define individual preposition scenes, then use these scenes to define the preposition tour. The tour starts from the lowest scene number in the tour and progresses sequentially to the highest scene number in the tour.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera To define a title for sectors: 7.28 1. Place the cursor in the input box to the right of the sector number. 2. Type a title for the sector, up to 20 characters long. 3. To blank the sector, click the check box to the right of the sector title. Miscellaneous Address Allows the appropriate dome to be operated via the numerical address in the control system.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 7.32 Advanced Mode: Recording 7.33 Storage Management 91 You can record the images from the AutoDome 800 Series on various local storage media or on an appropriately configured iSCSI system. It is also possible to let the VRM Video Recording Manager control all recording when accessing an iSCSI system. This is an external program for configuring recording tasks for video servers.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera storage media list. In the Status column, newly added media are indicated by the status Not active. 3. Click the Set button to activate all media in the Managed storage media list. In the Status column, these are indicated by the status Online. 4. Check the box in the Rec. 1 or Rec. 2 to specify which data stream should be recorded on the storage media selected. Rec. 1 stores Stream 1, Rec. 2 stores Stream 2.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 93 Standard recording Here you can select the mode for standard recordings. If you select Continuous, the recording proceeds continuously. If the maximum memory capacity is reached, older recordings will automatically be overwritten. If you select the Prealarm option, recording will only take place in the pre-alarm time, during the alarm and during the set post-alarm time. If you select Off, no automatic recording takes place.
en | Configuring the AutoDome 800 Series 7.35 AutoDome 800 Series HD PTZ Camera Retention Time You can specify the retention times for recordings. If the available memory capacity of a medium has been used, older recordings are only overwritten if the retention time entered here has expired. NOTICE! Make sure that the retention time corresponds with the available memory capacity.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 95 Time periods You can change the names of the recording profiles. 1. Click a profile and then the Rename button. 2. Enter your chosen name and then click the Rename button again. Activating the Recording After completing configuration you must activate the recording scheduler and start the recording.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera are to be possible, for example when initiating connections via higher-ranking systems such as VIDOS or Bosch Video Management System, you can store a general password here. The AutoDome 800 Series can use this general password to connect to all remote stations protected with the same password. In this case, proceed as follows: 1. Select 10 from the Number of destination IP address list field. 2. Enter the address 0.0.0.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 97 NOTICE! Please note that the SSL encryption must be activated and configured at both ends of a connection. This requires the appropriate certificates to be uploaded onto the AutoDome 800 Series. You can activate and configure encryption of the media data (video and metadata) on the Encryption page (see Section 7.54 Encryption, page 111).
en | Configuring the AutoDome 800 Series 1. AutoDome 800 Series HD PTZ Camera To rename the file, click the icon to the right of the list field and enter the new profile name in the field. 2. Click the icon again. The new profile name is saved. Alarm status The alarm status is displayed here for information purposes. This means you can check the effects of your settings immediately. Analysis type Select the required analysis algorithm.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 99 Debounce time 1 s (MOTION+ only) The debounce time is intended to prevent very brief alarm events from triggering individual alarms. If the Debounce time 1 s option is activated, an alarm event must last at least one second to trigger an alarm. Select Area (MOTION+ only) The areas of the image to be monitored by the motion detector can be selected. The video image is subdivided into 858 square fields.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera necessary for changes to occur simultaneously in a large number of sensor fields to trigger an alarm. This option allows you to detect, independently of motion alarms, manipulation of the orientation or location of a camera resulting from turning the camera mount bracket, for instance. Global change Activate this function if the global change, as set with the Global change slide control, should trigger an alarm.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 101 NOTICE! Select only those areas for reference monitoring in which no movement takes place and that are always evenly lit, as false alarms could otherwise be triggered. 1. Click Select Area to configure the sensor fields. A new window will open. 2. If necessary, click Clear All first to clear the current selection (fields marked yellow). 3. Left-click the fields to be activated. Activated fields are marked yellow. 4.
en | Configuring the AutoDome 800 Series 7.42 AutoDome 800 Series HD PTZ Camera Alarm E-Mail As an alternative to automatic connecting, alarm states can also be documented by e-mail. In this way it is possible to notify a recipient who does not have a video receiver. In this case, the AutoDome 800 Series automatically sends an e-mail to a previously defined e-mail address. Send alarm e-mail Select On if you want the unit to automatically send an alarm e-mail in the event of an alarm.
AutoDome 800 Series HD PTZ Camera 7.43 Configuring the AutoDome 800 Series | en 103 Alarm Task Editor CAUTION! Editing scripts on this page overwrites all settings and entries on the other alarm pages. This procedure cannot be reversed. In order to edit this page, you must have programming knowledge and be familiar with the information in the Alarm Task Script Language document.
en | Configuring the AutoDome 800 Series 3. AutoDome 800 Series HD PTZ Camera Choose one of the following output commands for both Output 1 and Output 2 settings: – None: no defined command. – Alarm Relay: defines a physical connection from the open collector alarm output. – Aux On: defines a standard or custom keyboard ON command. Refer to Section A Keyboard Commands by Number, page 116, for a list of valid commands. Note: Only commands 1, 2, 8, 18, 20, 43, 60, 78, 80, 86 are supported.
AutoDome 800 Series HD PTZ Camera – Configuring the AutoDome 800 Series | en 105 Remote Input 1 Relay Name You can assign a name for the relay here. The name is shown on the button next to Trigger relay. The Livepage can also be configured to display the name under the relay icon. You can also use the name in the Forensic Search program function as a filter option for quick search in recordings. Enter a unique and clear name here. CAUTION! Do not use any special characters, for example &, in the name.
en | Configuring the AutoDome 800 Series 7.49.2 AutoDome 800 Series HD PTZ Camera IPv6 Consult with the network administrator before making changes to the this section. IP Address Enter the desired IP address for the AutoDome 800 Series in this field. The IP address must be valid for the network. A typical IPv6 address may resemble the following example: 2001:db8 : : 52:1:1 Consult the network administrator for valid IPv6 address construction.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 107 You can activate and configure encryption of the media data (video and metadata) on the Encryption page (see Section 7.54 Encryption, page 111). RCP+ port 1756 To exchange connection data, you can activate the unsecured RCP+ port 1756. If you want connection data to be transmitted only when encrypted, select the Off option to deactivate the port.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera Status The status of the DynDNS function is displayed here for information purposes. You cannot change any of these settings. 7.50 Advanced The settings on this page are used to implement advanced settings for the network. Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot. 1. Make the desired changes. 2. Click the Set and Reboot button.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 109 NTCIP Specifies a set of rules and protocols for organizing, describing and exchanging transportation management information between transportation management applications and transportation equipment such that they interoperate with each other. Select a port for NTCIP and the Address from the appropriate drop-down lists. UPnP You can activate the Universal Plug and Play (UPnP) function.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera The multicast address can be the same for multiple streams. However, it will be necessary to use a different port in each case so that multiple data streams are not sent simultaneously using the same port and multicast address. NOTICE! The settings must be made individually for each stream. Enable To enable simultaneous data reception on several receivers you need to activate the multicast function. To do this, check the box.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 111 Posting interval Enter the interval in seconds at which the images will be sent to an FTP server. Enter zero if you do not want any images to be sent. FTP server IP address Enter the IP address of the FTP server on which you wish to save the JPEG images. FTP server login Enter your login name for the FTP server. FTP server password Enter the password that gives you access to the FTP server.
en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera CAUTION! Before launching the firmware upload make sure that you have selected the correct upload file. Uploading the wrong files can result in the unit no longer being addressable, in which case you must replace the unit. You should never interrupt the installation of firmware. An interruption can lead to the flashEPROM being incorrectly programmed.
AutoDome 800 Series HD PTZ Camera Configuring the AutoDome 800 Series | en 113 Configuration You can save configuration data for the AutoDome 800 Series on a computer and then load saved configuration data from a computer to the unit. Upload 1. 2. Enter the full path of the file to upload or click Browse to select the required file. Make certain that the file to be loaded comes from the same unit type as the unit you want to configure. 3. Next, click Upload to begin transferring the file to the unit.
AutoDome 800 Series HD PTZ Camera 8 Bubble Handling and Cleaning | en 113 Bubble Handling and Cleaning The bubble is made of acrylic for excellent optical clarity. Special care is required when handling and cleaning the bubble to avoid scratching it. 8.1 Handling The bubble is packaged with a protective plastic sheet. It is recommended that the bubble remain stored this way until it is ready to install. Limit handling the bubble, as any scratches can quickly affect visibility. 8.
114 en | Bubble Handling and Cleaning 8.2.2 AutoDome 800 Series HD PTZ Camera Cleaning the Bubble Exterior The exterior of the bubble is hard coated for extra protection. If cleaning becomes necessary, only use cleaning solutions and cloths suitable for cleaning safety glass lenses. Dry the bubble thoroughly with a dry nonabrasive cloth to prevent water spots. Never scrub the bubble with any abrasive material or cleaners. Do Not: – Do Not use abrasive or highly alkaline cleaners on the bubble.
AutoDome 800 Series HD PTZ Camera 9 BVIP Firmware Updates | en 115 BVIP Firmware Updates The AutoDome 800 Series incorporate a network video server in the IP module. The primary function of the server is to encode video and control data for transmission over a TCP/IP network. The AutoDome 800 Series also allows an operator to update the BVIP firmware via the TCP/IP network. The latest BVIP firmware is available on the Bosch Security Systems Web site.
116 en | AutoDome 800 Series HD PTZ Camera A Locked Keyboard Commands by Number Alarm Rule Function Key Comm No.
AutoDome 800 Series HD PTZ Camera Index | en 117 Index Symbols /reset 60 A activating the recording 95 activation key 112 alarm 77 alarm e-mail 102 alarm inputs 54 non-supervised 54 normally closed non-supervised 54 normally open non-supervised 54 with parapet roof or pipe mounts 47 with pendant arm, corner or mast mount 18, 24, 29 alarm message 77 alarm outputs 55 open collector output 55 with parapet roof or pipe mount 47 with pendant arm, corner or mast mount 18, 24, 29 alarm rule 103 alarm sensors 93
118 en | Index files JPEG 56 MPEG-4 56 firewall 96, 106 firmware upload 111 formatting 92 FTP server 110, 111 fuse specifications 19 G gateway 72, 105, 106 gateway address 58 general password 96 guard tour 88 guy-wire 45 H holidays 94 HTTP port 106 HTTPS port 106 I identification 70 IEEE 802.
AutoDome 800 Series HD PTZ Camera Index | en 119 P parapet arm stabilizing 45 password 62, 71, 74, 75 pendant connector harness 25, 30 pendant arm attaching to power supply box 22 pendant arm, corner or mast mount mast plate 16 pendant assembly attaching to pipe mount 49 pendant bubble removing 113 pipe interface board 46, 48 pipe mount 33, 45 power supply box location 34 pole installation 16, 26 port 58, 106, 110 post-alarm profile 93 post-alarm time 93 power supply fuse specifications 19 power supply bo
120 en | Index AutoDome 800 Series HD PTZ Camera U UDP 56, 96, 106 unicast 109 unit date 75 unit identification 70 unit name 70 unit time 71, 75 unshielded twisted pair with pendant arm, corner or mast mount 18 UPnP 109 user name 71, 75 UTP CAT-5 51 V VG4-A-9230 33, 42 VG4-ARMPLATE 15, 26 video content analysis 97 video sensor 97 VIDOS 56 VIP XD 56 VRM 91 W wall installation 16 wall mount template 16 for roof parapet or pipe mount 35 watermarking 77 wire standards 51 wiring for pendant arm, corner or
Bosch Security Systems, Inc. 850 Greenfield Road Lancaster, PA 17601 U.S.A. www.boschsecurity.com © Bosch Security Systems, Inc.