Installation Guide

34 en | Installing Roof Parapet and Pipe Mounts AutoDome 100 Series Fixed Camera
F.01U.217.818 | 1.0 | 2011.04 Installation Manual Bosch Security Systems, Inc.
3.1.3 Tools Required
5 mm Allen wrench (supplied)
Small straight blade screwdrivers ~ 2.5 mm (0.1 in.) – 3.1 mm (1/8 in.)
Medium straight blade screwdriver
No. 1 and No. 2 Phillips screwdrivers
Socket wrench and 9/16 in. socket
Pipe Wrench
Barrel connector (if installing a fiber optic model)
3.2 Pre-installation Check List
1. Determine the location and distance for the power supply box based on its voltage and
current consumption. Refer to Section 5 Cable and Wire Standards, page 61 for wiring
information and distances.
2. Use only UL listed liquid tight strain reliefs for conduits to the Power Supply Box to
ensure that water cannot enter the box. You must use water tight conduits and fittings to
meet NEMA 4 standards.
3. Install all rough wiring including: power, control, video coax, alarms I/O, relay I/O, and
fiber optic cabling. Refer to Section 5 Cable and Wire Standards, page 61 for video and
control protocol methods.
4. If you plan to use the RS232 or RS485 protocol to control the AutoDome, refer to
Section 5.4.2 Controlling the AutoDome via the RS232 Protocol, page 64, or
Section 5.4.3 Controlling the AutoDome via the RS485 Protocol, page 65, for instructions on
configuring the AutoDome to accept these protocols.
5. Choose the appropriate VG5 AutoDome model (indoor or outdoor) for the environment in
which it will be used.
6. Choose the appropriate mounting kit to use depending on the location of the AutoDome:
Parapet (Roof) mount or the Pipe mount.
NOTICE!
Power and I/O cabling must be routed separately inside different permanently earthed metal
conduits.
WARNING!
External interconnecting cables are to be installed in accordance to NEC, ANSI/NFPA70 (for
US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
accordance to local country codes for all other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated
Fuses are required as part of the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be incorporated.
CAUTION!
Select a rigid mounting location to prevent excessive vibration to the AutoDome camera.