AEGIS UFLED UFLED en Installation Manual
AEGIS UFLED Table of Contents | en 3 Table of Contents 1 Safety 4 1.1 Safety precautions 4 1.2 Important safety instructions 4 1.3 Important notices 5 1.4 Notifications 7 1.5 Certifications 8 1.6 FCC & ICES compliance 1.7 UL certification 10 8 1.8 Bosch notices 12 2 Overview 13 2.1 Features 13 2.2 Lens / Beam pattern matching 13 2.3 Achievable distances 14 3 Installation 15 3.1 Setting up 15 3.2 Connections 17 3.2.1 Telemetry input connection 19 3.2.
en | Safety AEGIS UFLED 1 Safety 1.1 Safety precautions DANGER! High risk: This symbol indicates an imminently hazardous situation such as “Dangerous Voltage” inside the product. If not avoided, this will result in an electrical shock, serious bodily injury, or death. WARNING! Medium risk: Indicates a potentially hazardous situation. If not avoided, this could result in minor or moderate bodily injury. CAUTION! Low risk: Indicates a potentially hazardous situation.
AEGIS UFLED Safety | en 5. 5 Controls adjustment - Adjust only those controls specified in the operating instructions. Improper adjustment of other controls may cause damage to the unit. 6. Power sources - Operate the unit only from the type of power source indicated on the label. 7. Servicing - Unless qualified, do not attempt to service this unit yourself. Refer all servicing to qualified service personnel. 8. Replacement parts - Use only replacement parts specified by the manufacturer. 9.
en | Safety AEGIS UFLED U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides information regarding proper grounding of the mount and supporting structure, grounding of the coax to a discharge unit, size of grounding conductors, location of discharge unit, connection to grounding electrodes, and requirements for the grounding electrode.
AEGIS UFLED 1.4 Safety | en 7 Notifications NOTICE! Class 3R notification for 850 nm models The product is tested and compliant to IEC/EN 60825-1 (2001) under normal operating conditions, and is classified as a Class 3R LED product. The measured output under the thermal hazard test (Class 1/3R) was 36.9 mW, peak at 850 nm wavelength.
en | Safety 1.5 AEGIS UFLED Certifications This product complies with European Directive 89/336/EEC and 73/23/EEC Low Voltage Directive meeting the following standards: Safety Electrical Safety: IEC/EN60598-2-5 C22.2 No. 250.0-08 UL 1598 EMC IP UL 2108 Eye Safety: IEC/EN60825-1 Radiated and Conducted EN55022:1998 Emissions Immunity FCC ICES-003 Issue 4:2004 EN50130-4:1995 CFR 47:2007 Part 15.107 & Ingress Protection 15.109 CLASS B LIMIT P67 in accordance with BS EN60529:1992 1.
AEGIS UFLED Safety | en – 9 increase the separation between the equipment and receiver; – connect the equipment into an outlet on a circuit different from that to which the receiver is connected; – consult the dealer or an experienced radio/TV technician for help. Intentional or unintentional modifications, not expressly approved by the party responsible for compliance, shall not be made. Any such modifications could void the user's authority to operate the equipment.
en | Safety AEGIS UFLED éliminer les interférences éventuelles en prenant une ou plusieurs des mesures suivantes: – Modifier l'orientation ou l'emplacement de l'antenne – Éloigner l'appareil du récepteur; – Brancher l'appareil sur une prise située sur un circuit – Consulter le revendeur ou un technicien qualifié en radio/ réceptrice; différent de celui du récepteur; télévision pour obtenir de l'aide.
AEGIS UFLED Safety | en 11 Disclaimer Underwriter Laboratories Inc. (“UL”) has not tested the performance or reliability of the security or signaling aspects of this product. UL has only tested fire, shock and/or casualty hazards as outlined in UP's Standard(s) for Safety for Information Technology Equipment, UL 60950-1. UL Certification does not cover the performance or reliability of the security or signaling aspects of this product.
en | Safety 1.8 AEGIS UFLED Bosch notices Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. Note: This manual has been compiled with great care and the information it contains has been thoroughly verified. The text was complete and correct at the time of printing.
AEGIS UFLED Overview | en 2 Overview 2.1 Features 13 The AEGIS UFLED range of infrared and white light illuminators for CCTV, features patent-pending illumination technology and installation friendly design.
en | Overview 2.3 AEGIS UFLED Achievable distances Illumination distance achievable depend on the characteristics of the CCD camera and lens used.
AEGIS UFLED Installation | en 3 Installation 3.1 Setting up 15 Set up the unit correctly to obtain the best performance. Optimum results are achieved by setting up at night and viewing the results on a monitor. Use the illustration below to assist with installation. Figure 3.1 Installing an AEGIS UFLED lamp 1 Nearest point 2 Furthest object CAUTION! When the unit has been operating for a while it becomes hot.
en | Installation 1. AEGIS UFLED Attach the illuminator to a pan and tilt unit, wall bracket or camera housing as required. 2. Connect the illuminator to a 12–24 VDC or to a 24 VAC (±15%, 50/60 Hz) power supply. 3. Commission the mains supply, camera, and monitoring control equipment. 4. Adjust the pan of the illuminator to match the camera’s field of view. 5. Loosen the bolts on each side of the unit and adjust the vertical alignment to maximize the results; re-tighten the bolts. 6.
AEGIS UFLED 3.2 Installation | en 17 Connections Figure 3.2 AEGIS Illuminator Rear Panel 1 2 Photocell Pressure Equalization 5 6 IR Power Adjustment Power Input 12 VDC/24 VAC 3 Vent Day/Night Camera 7 Photocell Sensitivity 4 Switching Telemetry Input Bosch Security Systems Installation Manual Adjustment F.01U.123.987 | 1.0 | 2010.
en | Installation AEGIS UFLED 2 1 4 2 1 4 3 3 COM N/O 1 2 4 3 N/C Figure 3.3 Wiring diagram Type of Connection 1 AC/DC Power In 2 Telemetry 3 Volt Free Day/Night Switching F.01U.123.987 | 1.0 | 2010.
AEGIS UFLED 3.2.1 Installation | en 19 Telemetry input connection The illuminator can be activated remotely by a remote switching device, camera signal or PIR. The telemetry input connection is a Normally Open (NO) contact that is switched by a volt-free contact across pins 1 (brown) and 3 (blue) of the connector cable. For this function to work correctly, the photocell must be disabled so that the illuminator is continuously On.
en | Installation AEGIS UFLED Note: Potentiometer Factory set at mid-point 500 Lux ON and 850 Lux OFF (approximately). Check the photocell functions by covering with black tape and having the telemetry link closed. The photocell operation has an in-built delay of up to 5 seconds. 3.2.4 Power adjustment To adjust power, first unscrew the sealing cap; the potentiometer is set at the maximum calibration point (fully clockwise). To decrease the power, turn the potentiometer counter clockwise.
AEGIS UFLED 3.3.2 Installation | en 21 Looping Multiple Illuminators Multiple illuminators can be linked for synchronous illuminator switching. Use link cable (UFLED-CL-1M) between the DAY/ NIGHT CAMERA output and the TELEMETRY input as shown in the diagram below. 1 2 3 4 5 6 3.3.3 UFLED Illuminator 1 UFLED Illuminator 2 UFLED Illuminator 3 Camera UFLED-CI-5M UFLED-CI-1M Illuminator Leading The DAY/NIGHT CAMERA output may be used to switch the camera between the Day and Night mode.
en | Specifications 4 AEGIS UFLED Specifications LEDs High efficiency Surface Mount LEDs with current Beam patterns Wavelength limited integral circuits 10°, 20°, 30°, 60°, 95°, 120° 850 nm, 940 nm and visible white light Average life Power Consumption (model dependent) > 10 years 26–45 W (45 W max power) Power consumption will vary over time due to optical output control which compensates for LED Input voltage degradation and ambient temperature fluctuations 12–24 VDC or 24 VAC Temp range I
AEGIS UFLED 4.1 Specifications | en 23 Dimensions 130.0 (5.12) 89.5 (3.52) 152.0 (5.98) mm (in.) Bosch Security Systems Installation Manual F.01U.123.987 | 1.0 | 2010.
en | Specifications F.01U.123.987 | 1.0 | 2010.