Installation manual

6 720 220 376
Subject to change without prior notice Revised 02-13
10 TSTBM3H2CPH6W-A
BASE MODULE
TSTBM3H2CPH6W-A
THERMOSTAT
R
C
W2
C
O
W/E
B
RH
RC
Y1
D
G
Y2
H
COMPRESSOR
SECTION
Y1
Y2
C
R
FAN COIL / AIR
HANDLER
R
G
Y1
Y2
C
W2
W1
2H/2C AIR CONDITIONING W/
ELECTRIC HEAT BACKUP
BASE MODULE
TSTBM3H2CPH6W-A
THERMOSTAT
R
C
W2
C
O
W1/E
B
RH
RC
Y1
D
G
Y2
H
PACKAGED
HEAT PUMP
Y1
Y2
R
G
C
O
B
W
JUMP "E" & "W2" AT THE TSTBM3H2CPH6W-A
THERMOSTAT WHEN THE HEAT PUMP EQUIPMENT
DOES NOT HAVE AN EMERGENCY HEAT TERMINAL