Operation Manual
12
Robert Bosch Hausgeräte GmbH
12 en
8. Attach the milk frother to the steam
valve. Check that the red mark on the
steam valve is covered.
¡
Risk of scalding!
Only use the appliance when the milk
frother (6) is completely assembled and
tted.
Cleaning the brewing unit
Clean the brewing unit regularly.
To pre-clean the brewing unit automatically:
1. Select e by turning the rotary knob (14).
2. Place an empty glass under outlet (7).
3. Press the start button (10).
The appliance rinses.
In addition to the automatic cleaning pro-
gramme, the brewing unit (5a) should be
removed regularly for cleaning. (See gure
E at the start of the operating instructions.)
1. Switch the appliance off at the power
on/off switch O / I (9). No buttons are lit.
2. Open the door (5b) to the brewing unit.
3. Slide the red lock (5d) on the brewing
unit completely to the left.
4. Press the red button (5c), grasp the
brewing unit by the recessed grips and
remove carefully.
5. Rinse the brewing unit (5a) thoroughly
under running water.
6. Hold the brewing unit sieve under the
running water.
Important: Do not clean with detergent or
other cleaning agents and do not put it in
the dishwasher.
7. Wipe out the inside of the appliance
thoroughly with a damp cloth and
remove any coffee residues.
8. Allow the brewing unit (5a) and the
inside of the appliance to dry.
9. Reinsert the brewing unit (5a) fully into
the appliance.
10. Slide the red lock (5d) fully to the right
and close the door (5b).
TES502_1RW.indb 12 21.02.2013 13:38:24