Installation Instructions
7
Electrical Connection
The dishwasher electrical supply junction box (L) and 
dedicated receptacle must be mounted in an accessible 
cabinet adjacent to the dishwasher (do not mount the junction 
box or receptacle behind the dishwasher). You will need a 
4
3
/4Ǝ[
3
/8Ǝ[PPRSHQLQJWKURXJKWKHFDELQHWLQ
order to pass the junction box through (see Figure 5). If the 
opening is made through wood, sand it smooth. If the opening 
is made through metal, use the included edge protector (G) 
or other approved method to protect wiring from damage. 
Use the four screws included (or appropriate fastener) in the 
parts bag to securely mount the junction box so that it can 
be easily accessed (see Figure 5). The electrical supply can 
be connected in two ways:
Method A - Three prong plug and receptacle
Use the included three-prong plug and junction box to 
FRQQHFWWR D GHGLFDWHG KRXVHKROG UHFHSWDFOH 0DNH VXUH
the household receptacle meets the electrical supply 
requirements as well as national and local codes.
Dedicated
Receptacle or 
Field Wiring
Dishwasher
Electrical Supply
Junction Box
Electric cord with
junction box and
three prong plug
are included 
with dishwasher
Electrical Supply
The customer has the responsibility of ensuring that the 
dishwasher electrical installation is in compliance with all 
national and local electrical codes and ordinances. The 
dishwasher is designed for an electrical supply of 120V, 
60 Hz, AC, connected to a dishwasher-dedicated, properly 
grounded electrical circuit with a fuse or breaker rated for 15 
amps. Electrical supply conductors shall be a minimum #14 
AWG copper wire rated at 75°C (167°F) or higher. 
Grounding Instructions
The dishwasher must be properly grounded before 
operating. This appliance must be connected to 
a grounded metal permanent wiring system, or an  
equipment grounding conductor must be run with the circuit 
conductors and connected to the equipment grounding 
WHUPLQDORU OHDG RQ WKH GLVKZDVKHU0DNH VXUH WKDW WKH
dishwasher is connected to a suitable ground in compliance 
with all local codes or, in the absence of a local code, with 
the NATIONAL ELECTRICAL CODE in the United States or 
the CANADIAN ELECTRIC CODE C22.1-latest edition in 
Canada as well as any provincial/state or municipal or local 
codes that apply.
Electrical Preparation 
Avoid Electrical Shock Hazard
Do not work on an energized circuit. Doing so 
could result in serious injury or death. Only 
TXDOL¿HG HOHFWULFLDQV VKRXOG SHUIRUP HOHFWULFDO
work. Do not attempt any work on the dishwasher 
electric supply circuit until you are certain the 
circuit is de-energized. 
Avoid Fire Hazard
Make sure electrical work is properly installed. 
2QO\TXDOL¿HGHOHFWULFLDQVVKRXOGSHUIRUP
electrical work.
WARNING
WARNING
Avoid Fire Hazard
Make sure there are no loose electrical connections. 
Make sure all electrical connections are properly 
made. 
WARNING
Dishwasher Electrical Rating
Volts Hertz Amperes Watts
120 60 15
1,450
(max)
12
Figure 5
Electrical Preparation
300
CLICK