Installation manual
Intrusion Control Panel Solution 64
Release Notes July, 2006
Release Notes for Version 1.05.01
In the interest of ongoing product development and improvement, Bosch is proud to release software version 1.05.01 for the
Solution 64 Intrusion Control Panel. This document briefly outlines the improvements added in this release.
Please read in conjunction with the current installation manual and other addendums for more detailed information.
1)
Zone Status Indicator (Green LED) Function Corrected.
Normally the Green Status indicator LED on the keypad will flash to
indicate that a zone or zones are unsealled and would remain on steady
when all zones are sealled.
If however the zone is an RF Zone which has been programmed for
pulse count and the zone remains open for longer than 10 seconds
then the status indicator will continue to flash even if the zone
reseals.
This issue is only relevant if the Zone is an RF Zone and it has been
programmed for pulse count.
This has been corrected in V1.05.01
2) RF Zone Pulse Count Function Corrected.
In previous versions any RF Zone programmed for pulse count
which was left unsealled when the area was armed would cause
an alarm to occur the next time the devices supervision signal was
received by the panel (approximatly 10 minutes after arming).
This has been corrected in V1.05.01