Installation manual

BLCC110 N1.10 Issue: FTR1.4 3/07
Release Notes Solution 64
6
Solution 64
© 2007 Bosch security Systems
www.boschsecuritysystems.com
32)
NEW
User RAS Security PIN Option Added.
A new option has been added in this release to allow for an
independant User connection to the panel using our Solution
Link End User programming software.
MENU 5-3-8, User RAS PIN option is defaulted to 00000000 and
is currently reserved for future use.
33)
NEW
Telephone Ring Count Analysis Changed.
The way ring counting is analysed for the Australian ring
tone has been changed in V1.10 to make it easy for new
users to learn and simpler to use when establishing a remote
connection.
In earlier versions, the panel would count rings as follows,
RING .. RING ......... RING .. RING would be counted as 1 ring.
In V1.10 the panel will now count rings as follows,
RING .. RING will be counted as 1 ring.
Occasionally you will hear half a ring at the moment the line is
switched through to the premises. In this case the panel will
count the rings as follows,
.. RING.........RING .. RING would be counted as 1 ring.
34)
NEW
Ring Count Default Changed.
To allow for the changes in the ring count analysis in V1.10 the
default ring count has been changed from 10 rings to 20 rings.
The maximum number of rings which can be programmed has
also been increased from 15 to 30 rings.
Comms > Remote Access >
Ring Count
MENU 5-3-3
0 = No Answer 20
1 to 30 = Answer Ring Count
This menu sets the number of rings the panel will wait until
answering an incoming call. Programming a zero will stop the
panel from answering any incoming calls.
Ring Count P001
20-20 Rings
Press  0-9 OK to SAVE
35) Output Event Assignment Default Changed.
The output event assignment option allows you to assign or
map an Output event to an Area number (1 to 8), a User number
(1 to 128), a Zone number (1 to 64) or a Group number (1 to 8)
that the output will follow.
Programming a zero will assign the output event to follow all
areas, users, zones or access groups depending on the event
type. Refer to Output Event Type Table in the Installation
manual for a complete listing of available options.
In Version 1.10 the default event assigment for all outputs has
been changed to 0.
Outputs > Properties >
Event Assignment
MENU 4-1-2
0 0 0
Event Assignment Op001
000
Press 0-9 OK to SAVE
36)
NEW
Keypad Emergency Alarm Triggers.
Version 1.10 introduces a new method for triggering keypad
Fire, Medical and Panic alarms.
The new methods are easier for the end user to remember and
also allow for labelling to be applied to the keypad further
simplifying operation. At this time both old and new methods
function.
NE W KEYPA D EM ER GE NC Y AL ARM T RI GG ER S
Key Sequence Event Triggered
Ë + Ê Hold for 2 seconds
Keypad Fire Alarm
Ê + È Hold for 2 seconds
Keypad Panic Alarm
È + Â Hold for 2 seconds
Keypad Medical Alarm
37) D Type Receiver Re-named Bosch Serial Receiver.
In Version 1.10 , Option 4 in MENU 3-5-0 has been re-named
from D Type Serial Rcvr to Bosch Serial Receiver. Both RF3212
and RF3212E receivers from Bosch are supported by this option.
i
Note
The following options are included in this release however
their functionality has been disabled as they are for future
use. Please ignore the following options in this release.
MENU 5-5 , MY Alarm
MENU 5-0-3 , Check Web Email
MENU 5-0-4 , Email System Log
MENU 5-0-8 , Register Customer
MENU 5-0-9 , Register Installer
MENU 5-3-8 , User RAS PIN