Installation manual

Solution 64
Bosch Security Systems | 12/05 | FTR1.1
3
20)
NEW
Key-Switch Open Close Option Added
Version 1.04 includes a new feature which allows you to select
whether or not a zone programmed as a Key-switch Zone, will
send opening and closing reports. The default is set to O.
Inputs > Global Input Options >
Input Options
MENU 3-4-2
1 Tamper On Short N
2 Reserved N
3 Response Time 500ms N
4 Reserved N
5 Keyswitch Open Close N
6 Reserved N
7 Reserved N
8 Reserved N
(*** System Wide Parameter ***)
21)
NEW
View RF Device ID
View RF I.D.
MENU 6-2-5
In version 1.04, the device ID display has been improved and
now also shows the device type and description within the
system as well as the RFid. The information for each transmission
will remain on the keypad display until either another
transmission is received from a dierent device or the OK key is
pressed.
22)
NEW
Clearing Temperature Alarms
In version 1.04, temperature alarms that are currently in eect
and being displayed in the scroll list will be cleared when
the temperature returns to normal or when exiting installer
programming mode.
It could take up to 1 minute for the alarm message to be
removed from the scroll list.
In earlier versions the temperature alarm would only clear if the
temperature returned to the normal range level.
23)
NEW
Chime Mode Options Added
In version 1.04 a new Chime Mode option has been added.
Areas > Commands >
Chime Mode
MENU 2-0-6
The Chime Mode option allows you to program how chime
zones will operate on an area by area basis.
Available options include;
Chime Always
Chime For 000 Seconds
Chime After 000 Seconds
It is now possible to stop the chime alarm if the door is left open
for a long period of time or to only trigger the chime alarm if the
door is left open for a period of time.
To set the required chime mode enter [MENU] + [2] + [0] + [6]
and select the area from the list then press [OK].
A001 Security System
A002 Area 2 Name
A003 Area 3 Name
Press  OK or MENU
Use the up and down arrow keys to select the required chime
mode. If the chosen type requires a time parameter use the right
arrow to move to the time eld and then use the up and down
arrow key to select the appropriate time. When nished press
[OK].
Chime Mode A001
Chime For 000 Seconds
Press  OK to SAVE
24)
NEW
Siren Trouble Display
Version 1.04 now displays Siren Trouble under the main heading
of Output Trouble. In earlier versions, the words Siren Trouble
would appear in the scroll list if Output 1 was missing. This fault
is now displayed under Output Trouble in the scroll list.
25)
NEW
Programming Domestic Phone Numbers
In earlier versions, if a comma was inserted into the dialling
sequence when entering Domestic Phone Numbers then the
panel would dial all digits up to the comma and then stop. This
has now been corrected in Version 1.04. This fault only aected
Domestic Phone Numbers. (comma = 2 second pause in the
dialling sequence)
26) Enrolling Tokens from External Readers
In version 1.03 it was not possible to learn tokens for users
higher than 15 via an external reader.
The restriction has been removed in V1.04 and it is now possible
to learn all users via an external reader.
27)
NEW
Ring Count Timing Change
The way the ring count option relates to actual time has been
changed in Version 1.04.
Now programming a Ring Count of 5 rings will cause the phone
to ring for 30 seconds and programming a ring count of 10 rings
will cause the phone to ring for ~ 1 minute before the panel
answers the call.
28)
NEW
Automatic Output Checking
Version 1.04 no longer checks outputs that have been marked as
not used.
In earlier versions, the system may have displayed faults for
outputs which were agged to be monitored but were set as not
used.