Installation manual

Solution 64
4 © 2006 Bosch Security Systems
www.boschsecuritysystems.com
BLCC110N1.04.04 Issue: FTR1.1 2/06
Release Notes Solution 64
19) Turn Area On / O Command Corrected
In previous versions, the Turn Area On / O option (MENU 2-0-1)
does not lter the user to restrict them from controlling an area
they don’t belong to.
In version 1.04.04 the panel lters the user and only provides
control for areas they are assigned to. A valid PIN is required in all
cases.
Areas > Commands >
Turn Area On/Off
-
-
MENU 2-0-1
20) Domestic Reporting and Pulse Dialling
In previous versions, if both the Domestic Reporting format
and pulse dialling option have been selected, the system may
not dial the complete phone number if it is longer than 6 digits.
This is due to the amount of time it takes to dial in pulse format
compared to DTMF dialling.
All other reporting formats are not eected even if pulse dialling
has been selected.
In version 1.04.04, the internal dial process timer has been
increased to 30 seconds which provides ample time to dial the
number in pulse or decadic format.
21) Walk Testing Fire Zones
In previous versions, placing a short across the EOL resistor to
test a re zone would not be accepted as a valid test and the
zone would remain in the untested zone list.
In version 1.04.04 the walk testing function has been changed to
allow a short across a re zone EOL resistor to be accepted as a
valid test.
22) RF Keyfob Panic Alarm Reporting
In earlier version, panic alarms trigger via RF keyfobs would
follow the status route when reporting the alarm. In domestic
dialling mode, the status route would typically be disabled and
this would prevent the keyfob panic for being transmitted.
In version 1.04.04 the reporting route for keyfob panic alarms
has been changed to the Emergency route which would not
normally be disabled when using domestic dialling.
i
Note
The following options are included in this release however
their functionality has been disabled as they are for future
use. Please ignore the following options in this release.
MENU 55 - MY Alarm
MENU 503 - Check Web Email
MENU 504 - Email System Log
MENU 508 -Register Customer
MENU 509 -Register Installer
23)
NEW
Tone Bypass Function Implemented
It is often dicult to establish a remote connection to a panel
if the customer picks up the phone or if a fax or answering
machine answers the call before the panel does.
While the ultimate solution to this problem is the use the CLI
Intelliconnect method, this requires the customer to enable CLI
via their telco provider.
When enabled, the new Tone Bypass option (MENU 5-3-4) tells
the panel to listen to every answered call and to look for a
specic sequence of DTMF tones.
The tone sequence will be sent by the remote programming
software and when the panel recognises them, it will
immediately seize the line away from the answering party and
the programming session will commence.
The feature requires Solution Link remote programming
software version 1.03 or higher.
Comms > Remote Access >
Solution Link RAS
Options
MENU 5-3-4
1 RAS Allowed Y
2 Call Back Verication Required N
3 Terminate RAS on Alarm Y
4 Answer Bypass Y
5 Answer Incoming Call Only If Armed N
6 Tone Bypass Y
7 Allow User Functions Via Remote Access Software Y
8 Report / Log RAS Start / End Sessions Y