Installation manual
Solution 64
Bosch Security Systems | 2/06 | FTR1.1
3
Should the trouble event still be in eect at 7am the keypad
beeper will start to sound. At all times the trouble event will be
displayed on the keypad and stored into the system log.
d) MENU 7-7-1 Reset Siren All Users
This option has been defaulted to YES because in most cases in
a partitioned system you would want all authorised users to be
able to reset the sirens.
System > System Options >
Area Options
MENU 7-7-1
1 Area 1 = Common Area N
2 First To Open Last To Close N
3 Reset Siren All Users ( All Areas) Y
4 Power Up In Same State As Powered Down Y
5 Fault Acknowledge All Areas Y
6 Delay Trouble Beeps Y
7 Reserved N
8 Reserved N
(*** System Wide Parameter ***)
e) MENU 2-1-1 Duress Allowed
This option has been defaulted to YES as there is very little
chance that a user would repeat the last two digits of their code
by accident when disarming.
Areas > Properties >
General Options
MENU 2-1-1
1 Exit Time Restart N
2 Reset Alarm Memory On Disarm N
3 Duress Allowed Y
4 Acknowledge All Faults N
5 Single Button Arming - All On Y
6 Single Button Arming - Part On Y
7 Link To Common Area Y
8 Single Button Part Off N
f) MENU 2-9-2 Service Interval
The default Service Interval has been changed to 000 weeks.
This means that from default, no service reminder will be given.
If you want to take advantage of this feature you will need to
program the number of weeks to wait between reminders into
this location.
Areas > Area Testing >
User Test Interval
MENU 2-9-1
0 0 0
(*** System Wide Parameter ***)
DAYS
14) RF Keyfob Panic Operation Corrected
In previous versions, triggering an RF Keyfob panic for any user
assigned to any area other than area 1, would cause the system
to loop on area 1, requiring a system power cycle to recover.
This has been corrected in the 1.04.04 release and the loop
function now increments through all areas on the system.
Users assigned to multiple areas are not eected provided they
also have access to Area 1.
15)
NEW
Auto Arming All Areas
In earlier versions, auto arming multiple areas required multiple
schedules.
In version 1.04.04 it is now possible to arm all areas using just 1
schedule. To do this select the corresponding auto arm schedule
and set it’s index to 000. See MENU 7-5-4.
System > Schedules >
Index
MENU 7-5-4
0
16) Recurring System Report Linked to Swinger Dialler Count.
In previous versions, a recurring system trouble event would
send a new report each time the event occurred, without any
swinger dialler override.
In V1.04.04 System Trouble events have been linked to the
swinger dialler setting in MENU 5-4-5. This means that a
recurring system trouble event will only report until the swinger
dialler count is reached and then it will be locked out. The event
will reactivate the next time any area is armed or disarmed.
System trouble events will only trigger the sirens, if applicable
once per arming cycle.
Comms > Dialler Reporting >
Swinger Dialler
MENU 5-4-5
(*** System Wide Parameter ***)
0 6
17) Display Output Status On Keypad Option
Changed
If the “Display Output Status On Keypad” option
(MENU 4-1-5) has been selected, and the output
in question is activated then a message will be
displayed in the scroll bar. In previous versions, if you
arm the panel while this massage is being displayed
then the system will prompt you to force arm the
output to complete the arming cycle.
In the 1.04.04 release, output status display messages
are now ltered out and the panel will not consider
these messages during the arming cycle.
18) PIN Always Required Option and Pop Up Boxes
In Version 1.04.04 , when the PIN Always Required
option is selected, and a pop up message box is
displayed, the system will prompt the user to Enter
PIN + OK to acknowledge the message.
In previous versions the system would prompt
Press OK, however this would not acknowledge the
message because no PIN had been entered.