Installation manual

Solution 64
2
Bosch Security Systems | 2/06 | FTR1.1
8)
NEW
Restrict Installer Access Per Keypad Option Added.
In installations with multiple keypads, you may want to restrict
the installer code access to one or a limited number of keypads.
For example you may want to restrict installer access to only
the keypad which is located in the communication room. To
congure this option, select “Installer PIN Not Allowed” option
for each required Keypad.
See MENU 6-1-5, Option 7 below.
9)
NEW
Prevent PIN Arm/Disarm Per Keypad Option Added.
Situations may arise where a keypad is required for access door
control only. In this situation to prevent Arm/ Disarm control, set
the “PIN Arming Not Allowed” option for each desired keypad .
Valid user codes with the appropriate access level can still be
used to operate the door strike from the keypad when this
option is set.
See MENU 6-1-5, Option 6 below.
Devices > Keypads >
Beeper Options
MENU 6-1-5
1 Trouble Alerts Y
2 Entry Warning Y
3 Exit Warning Y
4 Chime Tone Y
5 Display Temperature N
6 PIN Arming Not Allowed N
7 Installer PIN Not Allowed N
8 Show Alarm When Armed N
The above options can be congured independently for each
keypad tted to the system.
10) Manual Output Control with Inverted Polarity
In earlier versions, the keypad text prompts did not reect the
correct output polarity for outputs which are congured to be
on in the normal state.
For example Output 3 is defaulted to polarity type Low One Shot
Open, which means that in the normal state the output is on. In
version 1.04.04 the text prompts now correctly follow the output
polarity selected for each output.
11)
NEW
Zone Testing When Arming
When arming, the panel will notify the user about any zones
which are currently unsealed. At this point the user can abort the
arming process and seal the oending zone, or they can force
arm (if allowed) leaving the zone open in which case a trouble
will be reported.
In version 1.04.04, if the force arm prompt appears when arming,
the user can press the ON key again, and the system will re-scan
the zones. Any previously open zones that have re-sealed will
not trigger the force arm prompt after the re scan.
12) First To Open Last To Close Option Corrected
The rst to open last to close option, (MENU 7-7-1) did not
function correctly in previous versions.
This has been corrected in this release and the system now sends
a close report when all areas are armed, and an open report
when the rst area is disarmed.
System > System Options >
Area Options
MENU 7-7-1
1 Area 1 = Common Area N
2 First To Open Last To Close N
3 Reset Siren All Users ( All Areas) Y
4 Power Up In Same State As Powered Down Y
5 Fault Acknowledge All Areas Y
6 Delay Trouble Beeps Y
7 Reserved N
8 Reserved N
(*** System Wide Parameter ***)
13)
NEW
Panel Default Changes
A number of system defaults have been changed to better
reect the most commonly chosen options. See below.
a) MENU 6-6-2 Open Zone On Lost RF
This option has been defaulted to NO because when and RF
Zone fails it’s supervision check, a report is automatically sent to
the control room.
Device > RF Devices >
RF Device Options
MENU 6-2-2
1 Display RF Tamper Y
2 Report RF Tamper Y
3 Report RF Low Battery Y
4 Report Lost RF Device Y
5 Open Zone On Lost RF N
6 Audible Keyfob Panic Y
7 Report Keyfob Panic Y
8 Keyfob Function 1 Key = Part On Y
b) MENU 5-2-2 Alarm On Line Fail If Armed
This option has been defaulted to YES because more often than
not, if an intruder cuts the telco line you would want the sirens
to sound.
Comms > Properties >
Phone Line Options
MENU 5-2-2
1 Display Telephone Line Fail Y
2 Report Telephone Line Fail Y
3 Alarm On Line Fail If Armed Y
4 Alarm On Line Fail If Disarmed N
5 Reserved N
6 Reserved N
7 Reserved N
8 Display Phone In Use N
c) MENU 7-7-1 Delay Trouble Beeps
This option has been defaulted to YES based on customer
feedback. When set to YES the system will prevent trouble beeps
from the keypad between 10pm and 7am.