Installation manual
Intrusion Control Panel
Solution 64
Release Notes March, 2007
Security Systems
In the interest of ongoing product development and improvement, Bosch is proud to release software version 1 .50 for the
Solution 64 Security Control Panel. This document briefly outlines the new features and improvements added in this release.
Please read in conjunction with the current installation manual and other addendums for more detailed information.
To coincide with this release, we are pleased to also announce that Version 1.07 of our Solution Link Upload/Download software
is now available. Version 1.07 includes increased functionality, as well as support for the additional features in the V1.50
Solution 64 release.
Release Notes for Version 1.50.00
1)
NEW
Users Increased to 128.
Version 1.50 includes support for up to 128 users. Each user can
have a unique PIN number, Token and RF Keyfob if required.
Version 1.50 is supplied in all panels produced after March 2007.
It is not possible to upgrade panels manufactured earlier than
this date to 128 user capacity due to hardware differences.
The manufacture date can be found on the product
identification sticker located on the main PCB.
2)
NEW
Multi - Tenant Mode Added.
Version 1.50 includes additional support for multi-tennant
applications such as self storage garages or school storage
lockers etc.
When enabled, the new option Multi Tenant Mode option in
MENU 7-7-4 will lock the first 48 users on the system to the first
48 zones on the system. Each time the user enters their PIN the
corresponding zone is automtically bypassed allowing them to
access the zone (area).
Users 49 to 128 continue to operate as normal users.
System > Installer Options >
Installer Options
MENU 1-6-3
1 Report / Log Entry / Exit Installer Menu N
2 Report / Log Program Data Changed Y
3 Arm Only Installer PIN N
4 Zero Exit Time N
5 Auto Exit Installer Menu In 2 Hours Y
6 Auto Exit Service Mode In 2 Hours Y
7 Multi-tennant Mode N
8 Factory Defaulting Allowed Y
i
Note
A number of additional options and features in the
V1.50 release were originally released in V1.10.
To find out more, please take the time to also
read the release notes for V1.10.
Support for up to 128 User PIN Codes
Support for up to 128 Token Users
Support for up to 128 RF Keyfob Users
Support for Multi-Tenant Applications