Installation Guide

13
Grounding Instructions
The dishwasher must be properly grounded before operating. This appli-
ance must be connected to a grounded metal permanent wiring system or
an equipment grounding conductor must be run with the circuit conductors
and connected to the equipment grounding terminal or lead on the dish-
washer. Make sure that the dishwasher is connected to a suitable ground
in compliance with all local codes or, in the absence of a local code, with
the NATIONAL ELECTRICAL CODE in the United States or the CANADIAN
ELECTRIC CODE C22.1-latest edition in Canada as well as any provincial/
state or municipal or local codes that apply.
Note: Installations employing a Receptacle - The accessory cord kit, Model
SMZPC002UC, designed for connection to a receptacle is not provided, but
can be ordered through Customer Service by calling 1-800-944-2904. Make
sure the household receptacle meets the electrical supply requirements as
well as national and local codes. If you choose to permanently connect to
hardwiring, follow the next steps.
Dishwasher Electrical Rating
Volts Hertz Amperes Watts
120 60 12 1,440
(max)
Electrical Supply
The customer has the responsibility of ensuring that the dishwasher electri-
cal installation is in compliance with all national and local electrical codes
and ordinances. The dishwasher is designed for an electrical supply of
120V, 60 Hz, AC, connected to a dishwasher-dedicated, properly grounded
electrical circuit with a fuse or breaker rated for 15 amps. Electrical sup-
ply conductors shall be a minimum #14 AWG copper wire rated at 75°C
(167°F) or higher.