Electrical Specifications
The appliance comes with a 3-wire power supply cord. 
UL listed in the USA.
The appliance requires a 3-wire receptacle that is fitted with 
a 15 Amp fuse or higher. Refer to the following table for max 
load details.
The receptacle must be installed by a licensed electrician only.
For the installation position of the receptacle refer to diagram 
in “Electrical Location”.
Grounding Instruction
This appliance must be grounded. In the event of a malfunction 
or breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for the electric current.
Additional Grounding Procedure
Some local regulations may require a separate ground. In such 
cases, the required accessory ground wire, clamp and screw 
must be purchased separately. Never ground the appliance to 
plastic plumbing lines, gas lines or water pipes.
A 4-conductor cord shall be used when the appliance is 
installed in an area where local codes do not permit grounding 
through the neutral. Power supply cord must be replaced by a 
licensed electrician only.
Warning
Improper connection of the equipment grounding conductor 
may result in electric shock. Have the appliance checked by a 
qualified electrician or service technician if you are in doubt as 
to whether the appliance has been properly grounded.
Electrical Location
Side-by-Side Installation
Water Location
A cold water connection is required for appliances that feature 
an ice maker or an ice and water dispenser.
The water pressure must be between 40 and 120 p.s.i. 
(2.75‒8.25 bar). The installation must comply with local 
plumbing regulations.
A separate shut-off valve must be installed for the appliance 
water connection.
The shut-off valve for the water connection may not be behind 
the appliance. It is recommended to place the shut-off valve 
outside the cutout next to the appliance or in another easily 
accessible location. When installing the water connection, 
observe the permitted installation areas for the water supply 
line. The supply line can be located to the right (a), to the left 
(b), or underneath (c).
Appliance Max Load
120V AC, 60Hz
30-Inch Single Door Refrigerator 15 A
18-Inch Single Door Freezer* 15 A
30-Inch Bottom Freezer* 15 A
36-Inch French Door 15 A
*Including ice maker
Split Column Installation
18-Inch 30-Inch
X 18" (457 mm) 30" (762 mm)
Y 9" (229 mm) 15" (381 mm)