Setup guide
Table Of Contents
- Agencies
- About This Manual
- General Information
- Safety Symbols and Their Meanings
- Conflicts with Other Documents
- Table of Contents
- Figures
- Tables
- _
- 1.0 System Overview
- 1.1 System Components Description
- 1.2 Compatible Parts
- 1.3 System Components and Specifications
- 1.4 Transmitters
- 1.5 Cables
- 1.6 Batteries
- 1.7 Enclosures
- 1.8 Miscellaneous
- 2.0 Equipment Estimation
- 3.0 Installation Instructions
- 4.0 System Power-up and Debug
- 5.0 Testing and Troubleshooting
- _
- Appendix
Security Escort | Installation and Setup Guide |3.0
Installation Instructions
EN | 34
Bosch Security Systems | 1/09 | 33831E
Figure 14: EA500 Mounting to AE3 Enclosure
1
2
3
4
5
6
7
1 - AE3 Enclosure
2 - Circuit location
3 - Support post
4 - Battery location
5 - Circuit board
6 - Enclosure
7 - Support Post Assembly
Set the Address
Every transponder in the system must
have a unique address. Set the address
on the transponder using the DIP
switches in the upper-right corner.
Use the chart included in the
transponder installation guide for the
correct address settings.
Wiring
• Connect the bus wires.
• Connect the tamper switch wires.
• Connect the serial cable or SE485
wires (set the proper switch
position).
• Connect the output siren/strobe if
used.
• Connect the keyswitch if used.
• Connect 9 V output to ProxLink or
SE485 if used.
3.4.3 EA120 Alert Unit Installation
Mounting
The alert unit should be mounted
indoors; however, an outdoor enclosure
is available. The horn/strobe should
always be mounted outdoors.
Mount the circuit board to the
enclosure as indicated in
Figure 15
and
Figure 16.










