User manual
DCN Next Generation Open Interface Release 2.0 Voting
en | 141
szVotingSubject = “”;
szLegendSubject = “”;
This means that there is no subject text available on the unit LCD’s.
More information about the parameters can be found in section 3.2.7.
Voting parameters The voting parameters consist of various parameters which have the
following default values:
wVotingMenu = VT_C_MENU_YES_NO_ABSTAIN;
wNrOfAnswerOptions = 3;
bOpenVoting = FALSE;
wInterimResultType = VT_C_INT_RES_NONE;
More information about the parameters can be found in section 3.2.8.
General voting
settings
The general voting settings consists of many parameters which have
the following default values:
wVotingLedMode = VT_C_LED_SHOWVOTE;
wPresentVotes = VT_C_100_PRESENT_KEY;
bShowVoteTimer = FALSE;
wVoteTimerLimit = 0;
bReserved1 = FALSE;
bAutoAbstain = FALSE;
bReserved2 = TRUE;
bVoteWeightingOn = FALSE;
bReserved3 = FALSE;
bFirstVoteCount = FALSE;
More information about the parameters can be found in section 3.2.9.
2.5.1 Standalone settings
During startup of the DCNNG-system (power-on) the voting settings are set to their initial
values as described in §2.5.
However, when the DCNNG-system was controller by a Remote Controller, and new settings
were enabled. After stopping the voting application (Call to function VT_C_STOP_APP) some
voting settings remain active during the standalone period. These settings are:
Parameters Value
VT_C_SET_GLOBAL_SETTING remote function
wVotingLedMode This setting remains unchanged.
wPresentVotes In case VT_C_100_AUTHORISED_VOTES was
selected, the value of ‘wPresentVotes’ will change
to VT_C_100_VALID_VOTES.
For the others of ‘wPresentVotes’, the settings
remains unchanged.
bFirstVoteCounts This setting remains unchanged.
All other settings will return to their default values as described in §2.5.
The settings remain valid until either the power is turn off, or a remote controller is started,
which changes the settings.
2.6 Allowed settings without delegate-database present
The standard use of the voting application will be in combination with a downloaded delegate-
database.
However, it is possible to start a voting round without a downloaded delegate-database. In
this case the parameter value ranges are limited, because some settings require the
presence of a delegate-database.
In the table below an overview is given of the parameters with reduced setting due to the
absence of the delegate-database. The table shows the parameters of the remote functions
Bosch Security Systems B.V. | 2005 January | 9922 141 70542










