Technical data
Sample: Enabling the RF Device for Wireless Communication
1. Enter the Installer Code [1234] + [958] and press the [#] key.
2. Navigate to the RF MANAGER menu and press the [#] key.
The system guides you through the menu and displays the next menu item: RF SETTING.
1. Press the [#] key to get to the next menu item: RF RECEIVER.
2. Press the [#] key to get to the next menu item: RF RECEIVER ENABLE.
3. Enter 1 to enable the RF device and press the [#] key.
4. Press and hold the [–] key for 3 seconds to get to the EXIT PROG. +SAVE menu.
5. Press the [#] key to save the data end exit the programming mode.
Sample: Setting Up a Zone for an RF Device
1. Enter the Installer Code [1234] + [958] and press the [#] key.
2. Navigate to the ZONE MANAGER menu and press the (#] key.
The system guides you through the menu and displays the next menu item: ADD/DELETE
ZONES.
1. Press the [#] key to get to the next menu item: INPUT ZONE No.
2. Enter the zone number that you will set up (here 2) and press the [#] key.
The system displays the next menu item: ZONE MODULE SEL.
The following zone modules are available:
0 – on-board zone
1 – keypad zone
2 – dx2010 zone
3 – RF device – All, except RFGB / RF1100E and RFUN / RF3401E (Zone input only)
4 – RF device –RFGB / RF1100E (Glass Break Detector)
5 – RF device – RFUN / RF3401E (Zone input only)
15 – not used
Notice!
DEOL
DEOL is set as default for the wired zone. I.e., two resistances are used for wiring a line / an
input for tamper detection.
4 Enter the digit for the RF device (3, 4 or 5 depending on the device) and press the [#]
key.
The system displays the next menu item: ZONE FUNCTION.
4 Enter 1 for "Instant" and press the [#] key.
The system displays the next menu item: ZONE IN AREA.
4 Enter the area number that you will set up (here 1) and press the [#] key.
The system displays the next menu item: ZONE RFID: MANUAL.
1. Enter the RF ID manually (9 digits) and press the [#] key to confirm.
Or
Press and hold the [*] key for 3 seconds to switch to the ZONE RFID: AUTO menu item.
Trigger the RF device to give alarm once.
The RF ID will then be entered automatically.
Press the [#] key to confirm.
2. Press and hold the [–] key for 3 seconds to get back to the ADD/DELETE ZONES menu
item.
3. Press and hold the [–] key for 3 seconds to get to the EXIT PROG. +SAVE menu.
4. Press the [#] key to save the data end exit the programming mode.
5. Test the zones after you have terminated programming.