Technical data

Confirming the Input
4 Press the [#] key to confirm the input.
Switching between Settings
4 Press and hold the [*] key for 3 seconds to switch between settings.
Operating a Menu
1. Operate according to the menu prompt.
Select the menu and enter data for specific programming items according to the display
on the keypad to complete the programming, step by step.
2. Press the [#] key to confirm each step.
Exiting the Programming Mode
1. Complete all programming input by repeating the programming steps above and press the
[–] key to get back to the current main menu level by level.
2. Press and hold the [–] key for 3 seconds to get to the EXIT PROG. +SAVE menu.
It is optional to save or not to save the programming data.
1. Select EXIT PROG. +SAVE and press the [#] key to save the data and exit the
programming mode.
2. Select EXIT PROG. UNSAVED and press the [#] key to exit programming mode without
saving the data.
Programming the AMAX System
If the keypad is in standby mode, it gets enabled as soon as you press the first digit of your
code.
1. Make sure that the system is in a disarmed status (the STAY and AWAY indicators are
disabled).
2. Enter the Installer Code [1234] + [51] and press the [#] key to get to DATE/TIME.
The STAY and AWAY indicators flash to indicate the programming mode.
Setting Date and Time
After the system is powered up, date and time must be set. Otherwise, the system displays an
error.
1. Press the [#] key to get to the next menu item: CHANGE DATE/TIME.
2. Enter the current date and time by using the numeric keys and press the [#] key to
confirm.
3. Press and hold the [–] key for 3 seconds to get to the EXIT PROG. +SAVE menu.
4. Press the [#] key to save the data end exit the programming mode.
Sample: Deleting a Zone
The Zones 1-8 are enabled by default. Zone 1 is set as Delay, Zones 2-8 as Instant.
1. Enter the Installer Code [1234] + [958] and press the [#] key.
2. Navigate to the ZONE MANAGER menu and press the (#] key.
The system guides you through the menu and displays the next menu item: ADD/DELETE
ZONES.
1. Press the [#] key to get to the next menu item: INPUT ZONE No.
2. Enter the zone number that you will delete (here 1) and press the [#] key.
3. Press the [#] key again.
The system displays the next menu item: ZONE FUNCTION.
1. Enter 0 for "Not Used" and press the [#] key.
2. Press and hold the [–] key for 3 seconds to get back to the ADD/DELETE ZONES menu
item.
3. Press and hold the [–] key for 3 seconds to get to the EXIT PROG. +SAVE menu.
4. Press the [#] key to save the data end exit the programming mode.
5.1.4
AMAX 2100 / 3000 / 4000 Configuration | en 11
Bosch Sicherheitsysteme GmbH Quick Start Guide 2014.03 | 01 |