Specifications

Specifications
Dimensions 139.70 mm x 209.60 mm x 31.80 mm
(5.50 in x 8.25 in x 1.25 in)
Power/Voltage
(Standby battery)
16.5 VAC, 40VA (~)
Rated 3.7 VDC, 3050mAH EVE ENERGY CO Part No P0046-LF (Not user
replaceable). For standby battery to be operative, the tamper switch is
required to be engaged.
Transformer power/voltage Must meet country specific requirements
Current Draw 60 mA
Wire Gauge 0.65 mm (22 AWG) to 2.0 mm (18 AWG)
Temperature (operating) 0C to +49C (+32F to+120F)
Relative Humidity 0% to 93% (non-condensing)
Device testing To ensure proper functionality, the device must be tested at least once
every year by an installer.
Wall and Cover Tamper Switch Transmits a tamper signal when someone removes the device from its
base or pulls it away from the wall.
Frequency 433.42 MHz
Table 4.1: Specifications
LEDs
The repeater utilizes an external LED indicator to status the operation of the repeater. Refer to
the table below for LED descriptions.
LED Condition Pattern Description
On (Normal) Indicates the repeater is functioning normally.
Off Indicates there is a power failure to the repeater, or that the
receiver is not wired correctly.
Continuous Flash: 1 sec
rate for 5 sec
Indicates the repeater is being powered up, and conduction
manufacturing test initializations.
Continuous Flash: A 3-
pulse signal, followed by
a short delay after the 3
rd
pulse
Indicates the repeater has experienced a low battery
condition.
Continuous Flash: A 2
flash pattern continuous
pulse between On and
Off states with a short
delay after the 2
nd
pulse
Indicates an AC power failure is detected.
A communication failure within internal hardware
components inside the receiver
4.3
4.4
20 en | RADION repeater RADION receiver OP
02.2014 | 01 | F.01U.261.835 Reference Guide Bosch Security Systems, Inc