Specifications

Relative Humidity Up to 93% non-condensing
Frequency 433.42 MHz
Wiring Distance Maximum distance of 300 m (1000 ft) from
the control panel
Wiring Gauge 0.65 mm (22 AWG) to 2.0 mm (18 AWG)
maximum
Wall and Cover Tamper Switch – Transmits a tamper signal when the
device is removed from its base or
pulled away from the wall
Table 3.3: RFRC-OPT Specifications
Battery requirements
Notice!
Dispose of used batteries according to manufacturer’s instructions.
RADION Device Battery Size Battery Type Cell Voltage Quantity
(Cells)
RFPR-12 PIR
motion detector
CR123A Lithium 3 VDC 1
RFPR-C12 PIR
motion detector
(curtain)
CR123A Lithium 3 VDC 1
RFRP repeater Non-
replaceable
Lithium polymer 3.7 VDC nominal 1
RFSM smoke
detector
CR123A Lithium 3 VDC 2
RFUN universal
transmitter
CR123A Lithium 3 VDC 1
RFBT bill trap AAA Lithium 1.5 VDC 1
RFDL-11 TriTech
detector
AA Alkaline 1.5 VDC 4
RFDW-SM standard
door/window
contact
AAA Lithium 1.5 VDC 1
RFDW-RM
recessed door/
window contact
AAA Lithium 1.5 VDC 1
RFGB glassbreak CR123A Lithium 3 VDC 1
3.4.1
RADION receiver OP RADION receiver OP | en 17
Bosch Security Systems, Inc Reference Guide 02.2014 | 01 | F.01U.261.835