Technical data
TSplus Carousel Basic Equipment Guide R980 500 388 (6.2010)
Bosch Rexroth Corporation
29
WARNING!
Before starting up the conveyor for the
first time, re-check all mounting hard-
ware for tightness.
NOTE: The customer assumes respon-
sibility for the control system, and must
provide an EMERGENCY-OFF SWITCH
in the TSplus conveyor.
Connect the Motor Wiring
IMPORTANT!
All electrical wiring must be con-
nected by a qualified electrician.
The motor and gearbox are delivered
already mounted in the conveyor drive
module.
Make the motor electrical connec-
tions according to the connection
schematic shown in Fig. 38 and 39.
An additional copy is attached to the
motor nameplate.
CAUTION!
Verify correct motor rotation before
installing the chain. Reverse opera-
tion will cause severe damage to the
conveyor!
To check motor rotation:
Supply power to the motor to make
sure that the chain will be pulled in
the proper direction after it has been
fitted. The drive sprocket must rotate
so that the transport chain travels
along the top of the conveyor rails
toward the drive module.
Initial Start-Up
GND
L1
GND
L2
L3
Note: Transpose any two leads to reverse motor rotation
Y Connection
(High Voltage)
Y - Y Connection
(Low Voltage)
V1
U1
W1
V1
U1
W1
U3
V3 W3
U2 V2 W2
L1 L2
L3
V3
U3
W3
U2
V2 W2
W2
U2 V2
U1
V1 W1
TW
TW = Built in thermostat–normally closed, 135 C
Note: Transpose any two leads to reverse motor rotation
L3
L2
L1
W2
V2
U1
V1
W1
TW
L3
L2
L1
U2
Star Connection
(High Voltage)
Delta Connection
(Low Voltage)
Fig. 38