Technical data

8981 500 278 7/09
15
TSplus Assembly Conveyors
Bosch Rexroth Corporation
Maintenance
1 Inspect the lift-rotate unit every 1000
hours of operation for loose fasteners,
oil leaks, or any other signs of wear
or damage.
2 The gearmotor is sealed and lubri-
cated for the life of the unit and needs
no other maintenance.
3 The indexer should be checked for
proper oil level in the sight glass. If
oil is needed, use Mobil Gear 63 oil
or an equivalent (Fig. 9).
4 Wipe the indexer guide shafts with
mineral spirits to remove any dirt
buildup. Apply a very thin coating of
EP-0 grease to the guide shafts after
cleaning.
VENT
PLUG
OIL
LEVEL
SIGHT
GLASS
Fig. 9