Technical data

9
KTS 670: top model
with full set of equipment and features
Reliable application throughout
Ñ Intelligent and with a secure future due to
OBD-e
xchange adapter
Ñ Software-controlled by ESI[tronic]
Ñ Sim
ple connection to the vehicle
Ñ Clear communication via multiplexer and cable
adapter recognition: K and L line, SAE and CAN can
be
connected to all terminals on the OBD connector
Ñ New: OBD-exchange adapter integrated in the unit.
Ñ Simulation mode can be adjusted individually
Ñ Continuity tester for locating faults
Ñ Diode measurement for testing in components
Ñ Voltage measurement with enhanced measurement
functions
Ñ Current measurement with additional adaptation
option of FSA current clamps
Ñ Universal application for passenger cars and commer-
cial vehicles by means of universal OBD connector,
for 14 V and 28 V vehicle electrical systems
Order number
T
rolley 1 688 003 198
Trolley with charging tray 1 688 003 192
Upgrade kit (for KTS 670 to FSA 750) 1 687 001 593
KTS 670: core element of a professional diagnostic system
KTS 670:
equipped with
connections for
a secure future
}
Technical Data KTS 670
PC board Oper
ating system Windows XP,
1 GB main memory,
80 GB hard drive capacity
Display 12.1“ TFT color displa
y with touchscreen,
industrial standard, resulting in outstanding
brilliance and wide angle view;
resolution SVGA 800 x 600 dpi
Equipment Multimedia, built-in speak
er and headset
connection, installed LAN network card
(10/100 Mbit), PCMCIA standard
connection enables WLAN connection
Status indicator
Via 4 LEDs: On/Off, mains operation,
battery charge status, hard-drive access
Operation T
ouchscreen, 2 touch-sensitive keys;
On/Off button, special menu key
(backlighting control, virtual keyboard, etc
Lithium ionic battery
Service life depending upon charge status
and application approx. 1 to 2 hours
Housing S
table plastic housing, integrated impact
protection
Operating temperature 0 t
o 40 °C
Weight appr
ox. 4 kg
Dimension 400 x 125 x 300 mm (W x H x D)
Diagnostics protocols
ISO 9141-2, K/L lines, flashing code
SAE-J1850 VPW (GM, etc.) corresponds to
S
AE-J1850 PWM (Ford) ISO 11 519-4
CAN ISO 11898 ISO 15765-4 (OBD)
Highspeed, Middlespeed, Lowspeed
and Singlewire CAN
2-Kanal-Multimeter
Measured value accuracy 1 % from mean value
Zeroing option can be selected in the software,
measurement range 100 Ω to 1 MΩ, Voltage
measurement ranges apply to direct current
and alternating current, measurement range
+/-200 mV to +/-200 V(resolution 0.1 mV to
100 mV) Current monitoring via optional exter-
nal converters (current clamp, shunt), use of
FSA current clamp possible
2-channel
With 1-channel operation: 10 mega-samples/
oscilloscope sec, With 2-channel operation: 2 x 5 mega-
sam
ples/sec
Connections for
OBD diagnostics cable, adapter concept
“Easy Connect”, Uni 4 adapter and existing
adapter concept, Multimeter: channel 1: socket
yellow (+), blue (-), channel 2: red (+) and
black (ground), 2 x USB 2.0, LAN connection,
port jacks for contacts for stationary charger,
PS/2 for pointing device or keyboard, VGA for
external monitor, PCMCIA 2 x type 2 or 1 x
type 3, micro-in, line-out, headset
281336_04_717579_EN.indd 9 16.09.2008 15:10:33 Uhr