Technical data

R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 5-65
Standard Mode
5.5.17.7 Parallel Message System
RepmanSortCritP
RepoutNrP
RepoutDateP
Function Defines the sorting criteria for message output.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0 By priority of message number
1 In order of arrival (most recent first)
2 In order of arrival (oldest first)
The value of the variable is stored retentively. The stored value is auto-
matically used again after a power failure.
Function Allows you to output a message number along with the message.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0OFF
1ON
Function Allows you to output the date along with the message.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0OFF
1ON