Technical data

5-58 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
Standard Mode
ClearRepBuf
RepmanRepPrint
If you use the interface permanently for message output, it will not be
possible to send any other print jobs to the printer.
If you use the interface temporarily for message output, messages will
not be printed while other print jobs are being printed.
RepoutNr
Function Erases the memory for the serial messages.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0Inactive
1 Delete all messages from the message memory
2 Delete only the acknowledged messages from the message mem-
ory
Function Is used to have messages output to a printer.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0Inactive
1 Formatted output, the interface is used permanently.
2 Complete output, the interface is used permanently.
3 Formatted output, the interface is used temporarily.
4 Complete output, the interface is used temporarily.
The value of the variable is stored retentively. The stored value is auto-
matically used again after a power failure.
Function Allows you to output a message number along with the message.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0OFF
1ON