Technical data

R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 5-51
Standard Mode
ComSlaveNr
ComErrorCode
ComErrorSubcode
Function Sets the slave number for an operating device connected to a net-
work.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0 to
255
Slave number
Function Displays the last error code issued for a COMMUNICATION, SYS-
TEM, or FATAL error.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0 to
99999
By inserting this system variable into the message text of a message,
the error code will be stored in the message memory in addition to the
message.
See chapter “Serial Message System“ on page 5-171.
Function Displays the last error subcode (low word) issued for a COMMUNI-
CATION, SYSTEM, or FATAL error.
Data type Numeric
Representation
type
Positive decimal number, alphanumeric, selection text, selection im-
age, hexadecimal number, binary number
Configurable val-
ues
0 to
99999
By inserting this system variable into the message text of a message,
the error code will be stored in the message memory in addition to the
message.