Technical data
5-32 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
Standard Mode
The operating device uses the following formula to scale the output:
Fig. 5-23: Scaling of the output variables in the operating device
Use the following formula to determine the operands.
Fig. 5-24: Scaling of the output variables
The following example will help you determine the operands.
Example: Range of values for output values:
Lower limit for output value = 0
Upper limit for output value = 100
Current value in operating device = x
Range of values for controller values:
Lower limit for controller values = -4096
Upper limit for controller values = 4096
Current controller value = y
Operand Range of Values
Factor –32768 to –1, +1 to +32767
Divisor +1 to +32767
Addend –32768 to +32767
Fig. 5-21: Scaling decimal numbers
Operand Range of Values
Factor –999999999,99999999 to –
0,00000001+0,00000001 to +999999999,99999999
Divisor –999999999,99999999 to –
0,00000001+0,00000001 to +999999999,99999999
Addend –999999999,99999999 to +999999999,99999999
Fig. 5-22: Scaling floating point numbers
Output Value
of the Unit
=
Controller Value
x
Factor
Divisor
+
Summand
=
Current
Controller Value
-
Lower Limit
Controller Values
-
Lower Limit
Output Values
Current
Terminal Value
Upper Limit
Controller Values
-
Lower Limit
Controller Values
-
Lower Limit
Output Values
Upper Limit
Output Values