Technical data
R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 5-17
Standard Mode
If you specify a field height of 1, the system always only displays one
text from the text list. If the field height is greater than 1, a correspond-
ingly higher number of texts from the text list is displayed. The active
text is displayed inversely.
Example: For the parity of an interface the text items „no parity“, „odd“ and „even“
should be displayed instead of „0“, „1“ and „3“. Therefore create a text
list in the programming software with the following entries:
In the „selection text“ dialog of the programming software select the
name of the text list. Im Dialogfenster „Auswahltext“ von der Projek-
tierungssoftware wählen Sie anschließend den Namen der Textliste
aus. With this step you link the field for displaying the variable value
with the text list.
Key Function
0-9 No function
Decimal point No function
Plus Selection in ascending order (after the final value in
the text list is reached, the value at top of the text list
is selected next).
Minus Selection in descending order (after the first value in
the text list is reached, the value at the bottom of the
text list is selected next).
Cursor Right Moves the cursor one position to the right.
Cursor Left Moves the cursor one position to the left.
Cursor Up Moves the cursor to the next highest, editable vari-
able in the display, and selects it. If the cursor is al-
ready positioned at the top-level variable, the low-
est-level variable is selected.
Cursor Down Moves the cursor to the next lowest, editable vari-
able in the display, and selects it. If the cursor is al-
ready positioned at the lowest-level variable, the
top-level variable is selected.
Delete Deletes the character at the cursor position.
Fig. 5-9: Key functions for selection texts
Value Text
0 no parity
1 odd
2even
Fig. 5-10: Example of a text list