Technical data

5-8 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
Standard Mode
Password Protection for Setup Mask
A special procedure applies to password protection on the setup mask.
If you set the system variable MskchgPasswd as the first editable vari-
able on the setup mask, you can enter the password independently of
the access level (exception 255). This also allows you to set password
protection for the setup mask.
For the setup mask, the access level only impacts at the edit level,
meaning the content is always visible to the operator.
Suppressing the Setup Mask
You can choose to hide the setup mask if you do not need to display it.
To do this, set the access level for this mask to the value 255. The
setup mask can then not be accessed from the start-up mask (using
the Enter key or the Enter button).
5.4.3.2 Start-up Mask
The start-up mask appears for about five seconds after you switch on
the operating device. This time is fixed, and this cannot be changed.
On the start-up mask, you can only display static texts and system vari-
ables. Due to the time sequence used, it is not possible to enter vari-
ables here.
When the start-up mask is being displayed, you can press the Enter
key to go to the setup mask. You cannot go to the setup mask if the
access level of the setup mask is set to 255.
On the start-up mask, you can display the following information, for
example:
Service address
Machine type
Program version