Technical data

R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 6-141
PROFIBUS-DP raw
Protocol Parameters for the Bosch CL Series
Set the following parameters for the protocol:
Defining Variables
Specify the variable addresses in either the hexadecimal notation or
using the following syntax formats:
Fig. 6-212: Bit access for PROFIBUS using the Bosch CL series
Fig. 6-213: Byte access for PROFIBUS using the Bosch CL series
Fig. 6-214: Word access for PROFIBUS with the Bosch CL series
Fig. 6-215: Double-word access for PROFIBUS using the Bosch CL
series
Parameter Value
Maximum Waiting Time for Response [ms] 1000
Delay Until Connection Set-Up [ms] 5000
Station Number 3
Telegram Length 20
Floating Point Number in the Siemens Format Inactive
Byte Order is High-Low Inactive
Address Width 2
Fig. 6-211: Protocol parameters for the Bosch CL series