Technical data
6-136 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
PROFIBUS-DP raw
Parameterizing the call-up function:
Example: For two operating devices:
...
;DEF für Gerät 1
DEF 10,-EZ_Basisn
DEF 10,-AZ_Basisn
DEF DB50,-DBNR
DEF 0,-WDNR
DEF 20,-TLNG
;DEF für Gerät 2
DEF 10,-EZ_Basisn2
DEF 10,-AZ_Basisn2
DEF DB50,-DBNR2
DEF 0,-WDNR2
DEF 20,-TLNG2
;Aufruf Gerät 1
BA -BT_345,5 FC10
P0 W -EZ_Basisn
P1 W -AZ_Basisn
P2 -DBNR
P3 W -WDNR
P4 W -TLNG
;Aufruf Gerät 1
BA -BT_345,5 FC10
P0 W -EZ_Basisn2
P1 W -AZ_Basisn2
P2 -DBNR2
P3 W -WDNR2
P4 W -TLNG2
...
Function Block BT_PB345:
The function block BT_DP345 is used to decode the transfer protocol
of the operating devices. It ensures consistent data transfer.
When you program the controller, note that a total of 64 bytes as of the
address DB[P2] W[P3] are reserved for processing the protocol. Other
program components cannot use this area!
The function block BT_PB345 uses the following parameters:
Parameter Function
P0 EZ Base Address
P1 AZ Base Address
P2 Data block for storing the EZ/AZ data
P3 Base Address in Data Block [P2]
P4 Telegram Length
corresponds to the number of EZ/AZ data of the slave
configuration (8, 12, 16, 20, 28, or 32 bytes)
Fig. 6-205: Parameters for function block BT_PB345