Technical data
R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 6-131
PROFIBUS-DP raw
64 Protocol chip requires configuration update, re-
parameterization required.
65 No communication via protocol chip, reparame-
terization required.
66 Protocol chip reset, reparameterization required.
67 Watchdog time error, reparameterization re-
quired.
70 Operating device is not polled
0 Distinguishing feature for manufacturer
1 Distinguishing feature for manufacturer
71 xxx No response to order.
xxx = variable number
100 Base no. for error from PLC function block. PLC
error is added to 100. The subcode indicates the
offset value for the access, during which the er-
ror occurred.
z.B. 102 Access to DB via FB111 / FB112 DB does not
exist
Code Subcode Error Type Possible Cause
Fig. 6-200: Error Messages for PROFIBUS-DP