Technical data

R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 6-85
DeviceNet
6.6.5 Format of the Explicit Message High Byte
Class ID
(1 Byte)
Service ID
(1 Byte)
Instance ID
(1 Byte)
Service Data Service Name
Attribute ID
(1 Byte)
Data (n
Byte)
0x01
(Identity
Object)
0x01 0x01 Vendor ID Get Attribute SingleVendor
ID
0x02 Product
Type
Get Attribute SingleProduct
Type
0x03 Product
Code
Get Attribute SingleProduct
Code
0x04 VendorRevi-
sion
Get Attribute SingleVendor
Revision
0x05 ID Status Get Attribute SingleID Sta-
tus
0x06 Serial Num-
ber
Get Attribute SingleSerial
Number
0x07 Product
Name
Get Attribute SingleProduct
Name
0x05 N/A or 0x01 RESET
0x03 (De-
viceNet
Object)
0x0E (Get) 0x01 0x01 MAC ID Get Attribute Single MAC
ID
0x02 Baud Rate Get Attribute SingleBaud
Rate
0x03 BOI Get Attribute Single BOI
0x04 Bus Off
Counter
Get Attribute SingleBus Off
Counter
0x05 AllocationIn-
formation
Get Attribute SingleAlloca-
tion Information
Fig. 6-138: Format of the Explicit Message