Technical data
R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 6-75
DeviceNet
6.6.3 Programming
6.6.3.1 Protocol Parameters
With the protocol parameters, you can adapt the communication of the
controller used.
Baud Rate
This parameter specifies the communication rate.
Node Number
Use the node number to set the MAC ID for the operating device.
Delay until Connection Set-Up
Specify this value to set the period of time the operating device waits
before it sends the first Duplicate MAC ID Check Request Message.
Messages arriving before this time has elapsed are not evaluated.
Configurable
Values
(kBaud)
Default Value
125 X
250
500
Fig. 6-110: Baud rate, DeviceNet
Configurable
Values
Default Value
0 to 63 0
Fig. 6-111: Node number, DeviceNet
Configurable
Values
Default Value
5 s to 255 s 5 s
Fig. 6-112: Delay until connection set-up, DeviceNet