Technical data
R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 6-53
Bosch BUEP19
6.4.3.3 Cable X3 SER1 TTY / 20 mA - Bosch PU
The following cabling diagram applies to operating devices with a uni-
versal interface only.
Both ends of the shield are connected to the metallic housing.
Operating device
Transmitter ac-
tive
Receiver active
Bosch
e.g. Z301
Transmitter passive
Receiver passive
D-SUB
male connector
25 pin
D-SUB
male connector
25 pin
19 BN
T-
14 YE
R-
12WH
R-
21 WH
S1-
13
R+
16
S2+
10
T+
12
S1+
24 GN
S2-
23YE
T+
13GN
T-
22BN
R+
1