Technical data

6-38 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
IndraLogic
The type size multiplied by N provides the size of the message system
in bytes.
Date and Time
The variables for synchronizing the time and date must use the data
types USINT or ARRAY [1..N] OF BYTE.
6.3.3 Physical Interfacing
Plug-in connectors on the operating device for connection to the cont-
roller.
6.3.3.1 Pin assignment for operating devices with a universal interface
Variable Length
Date with a 2-digit year 3 Bytes
Date with a 4-digit year 4 Bytes
Time 3 Bytes
Weekday 1 Byte
Fig. 6-63: Byte lengths for the date and time
Pin Designation Function
6 TD Transmitted Data
15 CTS Clear to Send
17 RTS Request to Send
18 RD Received Data
25 SGND Signal Ground
Fig. 6-64: Pin assignment SER1 RS232
Pin Designation Function
8 T(A) Transmitted Data (-)
9 T(B) Transmitted Data (+)
11 SGND Signal Ground
22 R(A) Received Data (-)
23 R(B) Received Data (+)
Fig. 6-65: Pin assignment RS485