Technical data
R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 6-37
IndraLogic
Controllers
This parameter is reserved for future extensions.
Path for Variable List *.sym
This parameter specifies the directory in which the variable list *.sym is
stored.
To select a directory, click the Browse button.
The variable list *.sym is created by the programming software Indra-
Logic when compilation takes place.
6.3.2.2 System Parameters
Poll Area
The poll area is used to manage the write coordination byte, the serial
message channel and the LEDs in the function keys. This area is conti-
nuously polled by the operating device.
This protocol requires you to set up the poll area with three single vari-
ables.
Status Messages
Status messages are the static assignment of flags (bits) in the control-
ler to plain text messages in the operating device. For status message
addressing, use the data types BYTE, USINT, WORD, UINT, DWORD,
UDINT, or ARRAY[1..N]. The following applies when using ARRAY:
Configurable
Values
Default Value
Standard X
PLCWinNT
Fig. 6-61: Control
Area Valid Data Types
KBS (write coordination
byte)
BYTE, USINT, WORD, UINT
Message Channel WORD, UINT
Function Key LEDs BYTE, USINT, WORD, UINT, DWORD,
UDINT, ARRAY[1..N]
Fig. 6-62: Data types for the poll area