6-34 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
IndraLogic
6.3 IndraLogic
The protocol provides random read and write access to all global data
objects of the controller.
The programming software adopts the data objects of the
project_name.SYM file which are created when the IndraLogic project
is compiled.
The connected operating device uses the symbolic name to access a
data object.
6.3.1 Data Types
The length of a variable is determined by the length defined in the pro-
gramming software IndraLogic.
6.3.1.1 Single Variables
You can access variables of the following type: BOOL, BYTE, WORD,
DWORD, SINT, INT, DINT, USINT, UINT, UDINT, REAL, and
STRING. Floating point numbers are interpreted in IEEE format. The
variable type REAL is required for this purpose.
6.3.1.2 String Variables
For string variables, the variable type STRING(N) is used, where N is
the length of the string.
6.3.2 Programming
6.3.2.1 Protocol Parameters
Baud rate
This parameter specifies the communication rate.
Configurable
Values
(Baud)
Default Value
4800
Fig. 6-54: Baud rate