Technical data
R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 6-29
3S Serial
6.2.4 Error Messages
Error messages are displayed on the operating device along with a
code and subcode. Error messages are composed as follows.
Communication Error
Code XXXXX
Subcode XXXXX
Retries XXXXX
Code Subcode Error Type Possible Cause
50 03 Framing error on serial interface
05 CRC error on serial interface
06 Parity error on serial interface
60 10 Wrong telegram length
20 Wrong telegram Ident Number
30 Wrong block number
40 Wrong checksum
50 Negative acknowledgement
60 Waiting time exceeded: No response Cable interruption,
connection cut-off,
wrong baud rate
70 Error from the controller
Fig. 6-46: Error messages for 3S serial










