Technical data

R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 6-23
3S Serial
Stop Bits
This parameter specifies the number of stop bits.
Waiting Time for Response
Specify a waiting time for the Produced Data toggle bit monitoring.
Delay until Connection Set-Up
This parameter specifies the waiting time after which the operating
device starts the communication.
Byte Order
This parameter specifies the destination hardware's CPU type.
Configurable
Values
Default Value
1X
1.5
2
Fig. 6-36: Stop bits
Configurable
Values
Default Value
0 ms, 50 ms to
65000 ms
500 ms
Fig. 6-37: Waiting time for response
Configurable
Values
Default Value
5 s to 255 s 5 s
Fig. 6-38: Delay until Connection Set-Up
Configurable
Values
Default Value
Intel
Motorola X
Fig. 6-39: Byte order