Technical data

R911305038 / 01 | Rexroth VCP-Operating Concept Electric Drives and Controls | Bosch Rexroth AG 6-19
3964 RK512
6.1.5 Error Messages
Error messages are displayed on the operating device along with a
code and subcode. Error messages are composed as follows.
Communication Error
Code XXXXX
Subcode XXXXX
Retries XXXXX
Code Subcode Type of Error Possible Cause
1 Slave not ready Wrong slave address or
connecting cable not
plugged-in properly
2 Wrong character Wrong interface parame-
ters specified
3 Byte framing error
4 Waiting time elapsed (Timeout) Connection interrupted.
5 CRC or BCC error
6 Wrong parity
7 Send process aborted
8 Receive process aborted
9 Cyclic buffer overrun Cyclic buffer too small
10 No cyclic data defined
11 Cyclic data already defined
15 Protocol error The selected protocol is not
supported.
16 Receive buffer overrun
40 System variable error Undefined system variable
50 Invalid acknowledgement during connection set-
up
51 Invalid acknowledgement after transmission of
data
52 No response telegram
Fig. 6-32: Error messages - 3964/RK512