Technical data
6-12 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
3964 RK512
Coordination Flag
This parameter contains the number of the coordination flag you want
to use for the communication. Specifying a value of 255 in conjunction
with the bit number 15 deactivates the coordination function.
Bit Number
This parameter specifies the number of the bit in the coordination flag.
Specifying a value of 15 in conjunction with the coordination flag num-
ber 255 deactivates the coordination function.
Data Block Number
This parameter contains the number of the data block to be used for
the exchange of controller data.
Data Block Word
This parameter specifies the offset of the data within the data block.
Configurable
Values
Default value
0 to 255 0
Fig. 6-16: Coordination flag, 3964 RK512
Configurable
Values
Default value
0 to 15 0
Fig. 6-17: Bit number, 3964 RK512
Configurable
Values
Default value
Any values within the
addressing range.
10
Fig. 6-18: Data block number, 3964 RK512
Configurable
Values
Default value
Any values within the
addressing range.
0
Fig. 6-19: Data block Word, 3964 RK512