Technical data

5-192 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
Standard Mode
For each mask change, the operating device writes the current mask
number in this variable. The mask number represents a mask-specific
code.
This means that you can access the user interface from the controller.
5.28 Image of User Mode Switch
In standard mode, the image of the user mode switch is transferred to
the controller after the initialization phase is complete. You can choose
to have any unassigned DIP-switches evaluated by the controller. This
allows you to call up specific programs or to create queries in a service
routine.
5.29 Screen Saver
Some operating devices are fitted with a screen saver. This function
monitors all outputs to the display. If the system detects that nothing is
being output to the display, a timeout begins to elapse. After the time-
out has elapsed, the display is blanked and the status LED in the Help
key begins to flash. The display can be reactivated by pressing any
key. Activation of the screen saver can be made dependent on the dis-
play of cyclical variables.
The monitoring time can be defined in 0.1 second steps. If you enter
the value 0 for the time, the screen saver remains deactivated.
5.30 Documentation
You can document the entire content of a project in an RTF file. To
determine the scope of documentation, select the required project ele-
ments that are arranged in a tree structure.
You can fine-tune the documentation layout by selecting and deselect-
ing different documentation parameters.
5.30.1 Documentation Parameters
You can use the documentation parameters to influence the layout of
the documentation to be generated for the selected elements of a
project.
5.30.1.1 Global Settings
Select whether you would like the mask reference lists in the document
to be specified by name, or whether the current mask will be specified
for a predefined variable value.