Technical data
5-190 Bosch Rexroth AG | Electric Drives and Controls Rexroth VCP-Operating Concept | R911305038 / 01
Standard Mode
The following table illustrates the memory use for 500 messages and a
maximum number of data sets containing 22 bytes of user data:
You can use the following formula to determine the exact message
buffer size:
G >= M1 + M3 + 20
G = Size of message buffer
B = Size of parallel message system in bytes
M1 = Number of messages which: require only 1 memory location, are
entered in the message editor and have message numbers smaller
than B x 8
M3 = Number of messages which: require 3 memory locations, are
entered in the message editor and have message numbers smaller
than B x 8
20 = Minimum size of message buffer
5.25 Application ID
You can use the application ID to identify any application.
The application ID is stored in the project’s S3 file and is therefore
stored in the operating device after the download. The same ID is
stored in the project management file.
You can compare the IDs of a project management file with that of an
S3 file.
You can also compare the IDs of an S3 file and operating device con-
tent. To do this, you must establish a connection between the PC and
the operating device (download cable).
Z80-CPU 32 Bit RISC CPU
Available Memory Space in Bytes About
116000
About 116000 for FW version 1.07 or lower
About 147000 for FW version 1.08 or higher
Memory Requirement for Mes-
sage in Bytes
24 x 500 =
1200
32 x 500 = 16000
Remaining Memory Capacity in
Bytes
104000 About 100000 for FW version 1.07 or lower
About 1294000 for FW version 1.08 or higher
Possible Number of Data Sets 104000 /
(22+33) =
1890
100000 / (22+44) = 1515 for FW version 1.07 or
lower
1294000 / (22+44) = 1960 for FW version 1.08 or
higher
Fig. 5-76: Memory use for 500 messages in comparison